English
Language : 

TL284X_07 Datasheet, PDF (4/18 Pages) Texas Instruments – CURRENT-MODE PWM CONTROLLERS
TL284x, TL384x
CURRENT-MODE PWM CONTROLLERS
SLVS038F – JANUARY 1989 – REVISED FEBRUARY 2003
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage (see Note 1) (ICC < 30 mA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Self limiting
Analog input voltage range, VI (VFB and ISENSE) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 6.3 V
Output voltage, VO (OUTPUT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 V
Input voltage, VI, (VC, D package only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 V
Supply current, ICC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 mA
Output current, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±1 A
Error amplifier output sink current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 mA
Package thermal impedance, θJA (see Notes 2 and 3): D package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86°C/W
D-8 package . . . . . . . . . . . . . . . . . . . . . . . . . . 97°C/W
P package . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85°C/W
Virtual junction temperature, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150°C
Output energy (capacitive load) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 µJ
Lead temperature, 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltages are with respect to the device GND terminal.
2. Maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any allowable
ambient temperature is PD = (TJ(max) – TA)/θJA. Operating at the absolute maximum TJ of 150°C can impact reliability.
3. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions
VCC and VC‡
VI, RT/CT
VI, VFB and ISENSE
VO, OUTPUT
VO, POWER GROUND‡
ICC
IO
IO(ref)
fosc
Supply voltage
Input voltage
Input voltage
Output voltage
Output voltage
Supply current, externally limited
Average output current
Reference output current
Oscillator frequency
TA
Operating free-air temperature
‡ These recommended voltages for VC and POWER GROUND apply only to the D package.
TL284x
TL384x
MIN NOM MAX UNIT
30 V
0
5.5 V
0
5.5 V
0
30 V
–0.1
1V
25 mA
200 mA
–20 mA
100 500 kHz
–40
85
°C
0
70
4
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265