English
Language : 

LP38859_15 Datasheet, PDF (5/25 Pages) Texas Instruments – 3A Fast-Response High-Accuracy LDO Linear Regulator With Soft Start
www.ti.com
LP38859
SNVS337F – JUNE 2006 – REVISED SEPTEMBER 2015
6.5 Electrical Characteristics
Unless otherwise specified: VIN = VOUT(NOM) + 1 V, VBIAS = 3 V, IOUT = 10 mA, CIN = COUT = 10 µF, CBIAS = 1 µF, CSS = open.
Typical limits apply for TJ = 25°C; minimum and maximum limits apply over the junction temperature (TJ) range of -40°C to
+125°C, unless otherwise specified. Minimum and maximum limits are specified through test, design, or statistical correlation.
Typical values represent the most likely parametric norm at TJ = 25°C, and are provided for reference purposes only.
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX UNIT
VOUT
ΔVOUT/ΔVIN
ΔVOUT/ΔVBIAS
ΔVOUT/ΔIOUT
VDO
IGND(IN)
IGND(BIAS)
UVLO
UVLO(HYS)
VOUT accuracy
Line regulation, VIN(1)
Line regulation, VBIAS(1)
Output voltage load regulation(2)
Dropout voltage(3)
Quiescent current drawn from
VIN supply
Quiescent current drawn from
VBIAS supply
Undervoltage lockout threshold
Undervoltage lockout hysteresis
VOUT(NOM) + 1 V ≤ VIN ≤ VBIAS
3 V ≤ VBIAS ≤ 5.5 V
10 mA ≤ IOUT ≤ 3 A, TJ = 25°C
VOUT(NOM) + 1 V ≤ VIN ≤ VBIAS
3 V ≤ VBIAS ≤ 5.5 V
10 mA ≤ IOUT ≤ 3 A
VOUT(NOM) + 1 V ≤ VIN ≤ VBIAS
3 V ≤ VBIAS ≤ 5.5 V
10 mA ≤ IOUT ≤ 3 A
0°C ≤ TJ ≤ +125°C
VOUT(NOM) + 1 V ≤ VIN ≤ VBIAS
3 V ≤ VBIAS ≤ 5.5 V
10 mA ≤ IOUT ≤ 3 A
IOUT = 3 A, TJ = 25°C
IOUT = 3 A
LP38859-0.8
10 mA ≤ IOUT ≤ 3 A, TJ = 25°C
LP38859-0.8
10 mA ≤ IOUT ≤ 3 A
LP38859-1.2
10 mA ≤ IOUT ≤ 3 A, TJ = 25°C
LP38859-1.2
10 mA ≤ IOUT ≤ 3 A
10 mA ≤ IOUT ≤ 3 A, TJ = 25°C
10 mA ≤ IOUT ≤ 3 A
VBIAS rising until device is functional
TJ = 25°C
VBIAS rising until device is functional
VBIAS falling from UVLO threshold
until device is non-functional
TJ = 25°C
VBIAS falling from UVLO threshold
until device is non-functional
-1%
1%
–3%
3%
–2%
0.04
0.10
0.2
240
7
11
3
2.2
2.45
2
60
150
50
2%
%/V
%/V
%/A
300
mV
450
8.5
9
mA
12
15
3.8
mA
4.5
2.7
V
2.9
300
mV
350
ISC
SOFT-START
Output short-circuit current
VIN = VOUT(NOM) + 1 V
VBIAS = 3 V, VOUT = 0 V
6.2
A
LP38859-0.8
rSS
Soft-start internal resistance
LP38859-1.2
11
13.5
16
kΩ
13.5
16
18.5
tSS
Soft-start time
tSS = CSS × rSS × 5
LP38859-0.8, CSS = 10 nF
LP38859-1.2, CSS = 10 nF
675
μs
800
(1) Output voltage line regulation is defined as the change in output voltage from nominal value resulting from a change in input voltage.
(2) Output voltage load regulation is defined as the change in output voltage from nominal value as the load current increases from no load
to full load.
(3) Dropout voltage is defined the as input to output voltage differential (VIN – VOUT) where the input voltage is low enough to cause the
output voltage to drop no more than 2% from the nominal value.
Copyright © 2006–2015, Texas Instruments Incorporated
Product Folder Links: LP38859
Submit Documentation Feedback
5