English
Language : 

BQ20Z45 Datasheet, PDF (5/20 Pages) Texas Instruments – SBS 1.1-Compliant Gas Gauge and Protection Enabled With Impedance Track™
bq20z45
www.ti.com .................................................................................................................................................................................................. SLUS800 – MARCH 2009
ELECTRICAL CHARACTERISTICS
over operating free-air temperature range (unless otherwise noted), TA = –40°C to 85°C, V(REG25) = 2.41 V to 2.59 V,
V(BAT) = 14 V, C(REG25) = 1 µF, C(REG33) = 2.2 µF; typical values at TA = 25°C (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
SUPPLY CURRENT
I(NORMAL)
Firmware running
550
I(SLEEP)
Sleep Mode
CHG FET on; DSG FET on
124
CHG FET off; DSG FET on
90
CHG FET off; DSG FET off
52
I(SHUTDOWN)
Shutdown Mode
SHUTDOWN WAKE; TA = 25°C (unless otherwise noted)
I(PACK)
Shutdown exit at VSTARTUP threshold
SRx WAKE FROM SLEEP; TA = 25°C (unless otherwise noted)
V(WAKE)
Positive or negative wake threshold
with 1.00 mV, 2.25 mV, 4.5 mV and 9
mV programmable options
0.1
1
1
1.25
10
V(WAKE_ACR)
V(WAKE_TCO)
t(WAKE)
Accuracy of V(WAKE)
Temperature drift of V(WAKE) accuracy
Time from application of current and
wake of bq8040
V(WAKE) = 1 mV;
I(WAKE)= 0, RSNS1 = 0, RSNS0 = 1;
V(WAKE) = 2.25 mV;
I(WAKE) = 1, RSNS1 = 0, RSNS0 = 1;
I(WAKE) = 0, RSNS1 = 1, RSNS0 = 0;
V(WAKE) = 4.5 mV;
I(WAKE) = 1, RSNS1 = 1, RSNS0 = 1;
I(WAKE) = 0, RSNS1 = 1, RSNS0 = 0;
V(WAKE) = 9 mV;
I(WAKE) = 1, RSNS1 = 1, RSNS0 = 1;
-0.7
0.7
-0.8
0.8
-1.0
1.0
-1.4
1.4
0.5
1
10
POWER-ON RESET
VIT–
Negative-going voltage input
Voltage at REG25 pin
Vhys
Hysteresis
VIT+ – VIT-
tRST
RESET active low time
active low time after power up or
watchdog reset
1.70
1.80
1.90
50
150
250
100
250
560
WATCHDOG TIMER
tWDTINT
Watchdog start up detect time
tWDWT
Watchdog detect time
2.5V LDO; I(REG33OUT) = 0 mA; TA = 25°C (unless otherwise noted)
V(REG25)
Regulator output voltage
4.5 < VCC or BAT < 25 V;
I(REG25OUT) ≤ 16 mA;
TA = –40°C to 100°C
ΔV(REG25TEMP)
Regulator output change with
temperature
I(REG25OUT) = 2 mA;
TA = –40°C to 100°C
ΔV(REG25LINE)
Line regulation
5.4 < VCC or BAT < 25 V;
I(REG25OUT) = 2 mA
ΔV(REG25LOAD) Load Regulation
0.2 mA ≤ I(REG25OUT) ≤ 2 mA
0.2 mA ≤ I(REG25OUT) ≤ 16 mA
I(REG25MAX)
Current Limit
drawing current until
REG25 = 2 V to 0 V
250
500
50
100
2.41
2.5
±0.2
3
7
25
5
40
1000
150
2.59
10
25
50
75
3.3V LDO; I(REG25OUT) = 0 mA; TA = 25°C (unless otherwise noted)
V(REG33)
Regulator output voltage
4.5 < VCC or BAT < 25 V;
I(REG33OUT) ≤ 25 mA;
TA = –40°C to 100°C
ΔV(REG33TEMP)
Regulator output change with
temperature
I(REG33OUT) = 2 mA;
TA = –40°C to 100°C
ΔV(REG33LINE)
Line regulation
5.4 < VCC or BAT < 25 V;
I(REG33OUT) = 2 mA
ΔV(REG33LOAD) Load Regulation
0.2 mA ≤ I(REG33OUT) ≤ 2 mA
0.2mA ≤ I(REG33OUT) ≤ 25 mA
3
3.3
3.6
±0.2
3
10
7
17
40
100
UNIT
µA
µA
µA
µA
µA
µA
mV
mV
%/°C
ms
V
mV
µs
ms
µs
V
%
mV
mV
mA
V
%
mV
mV
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): bq20z45
Submit Documentation Feedback
5