TLC5618, TLC5618A
PROGRAMMABLE DUAL 12-BIT DIGITAL-TO-ANALOG CONVERTERS
SLAS156E – JULY 1997 – REVISED SEPTEMBER 1999
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage (VDD to AGND) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Digital input voltage range to AGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to VDD + 0.3 V
Reference input voltage range to AGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.3 V to VDD + 0.3 V
Output voltage at OUT from external source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VDD + 0.3 V
Continuous current at any terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Operating free-air temperature range, TA: TLC5618C, TLC5618AC . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
TLC5618I, TLC5618AI . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 85°C
TLC5618AQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 125°C
TLC5618AM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
DISSIPATION RATING TABLE
PACKAGE
TA ≤ 25°C
POWER RATING
DERATING FACTOR
ABOVE TA = 25°C‡
TA = 70°C
POWER RATING
TA = 85°C
POWER RATING
TA = 125°C
POWER RATING
D
635 mW
5.08 mW/°C
407 mW
330 mW
—
FK
1375 mW
11.00 mW/°C
880 mW
715 mW
275 mW
JG
1050 mW
8.40 mW/°C
672 mW
546 mW
210 mW
P
1202 mW
9.61 mW/°C
769 mW
625 mW
—
‡ This is the inverse of the traditional Junction-to-Ambient thermal Resistance (RΘJA). Thermal Resistances are not production tested and are for
informational purposes only.
recommended operating conditions
Supply voltage, VDD
High-level digital input voltage, VIH
Low-level digital input voltage, VIL
Reference voltage, Vref to REFIN terminal
Load resistance, RL
Operating free-air temperature, TA
VDD = 5 V
VDD = 5 V
TLC5618C, TLC5618AC
TLC5618I, TLC5618AI
TLC5618AQ
TLC5618AM
MIN
4.5
0.7 VDD
2
2
0
– 40
– 40
– 55
NOM
5
2.048
MAX
5.5
0.3 VDD
VDD – 1.1
70
85
125
125
UNIT
V
V
V
V
kΩ
°C
4
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265