TLC2274ACPW Datasheet, PDF (4/52 Pages) Texas Instruments – Advanced LinCMOSE RAIL-TO-RAIL OPERATIONAL AMPLIFIERS
TLC227x, TLC227xA
Advanced LinCMOS™ RAIL-TO-RAIL
OPERATIONAL AMPLIFIERS
SLOS190B – FEBRUARY 1997 – REVISED JULY 1999
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, VDD + (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 V
Supply voltage, VDD – (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 8 V
Differential input voltage, VID (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 16 V
Input voltage, VI (any input, see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VDD– – 0.3 V to VDD+
Input current, II (any input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 5 mA
Output current, IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Total current into VDD + . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Total current out of VDD – . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Duration of short-circuit current at (or below) 25°C (see Note 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . unlimited
Continuous total dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table
Operating free-air temperature range, TA: C suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
I suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 85°C
Q suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 40°C to 125°C
M suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D, N, P or PW package . . . . . . . . . . 260°C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: J package . . . . . . . . . . . . . . . . . . . . . 300°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, except differential voltages, are with respect to the midpoint between VDD+ and VDD –.
2. Differential voltages are at IN+ with respect to IN –. Excessive current will flow if input is brought below VDD – – 0.3 V.
3. The output may be shorted to either supply. Temperature and/or supply voltages must be limited to ensure that the maximum
dissipation rating is not exceeded.
PACKAGE
D–8
D–14
FK
J
N
P
PW–8
PW–14
TA ≤ 25°C
POWER RATING
725 mW
950 mW
1375 mW
1375 mW
1150 mW
1000 mW
525 mW
700 mW
DISSIPATION RATING TABLE
DERATING FACTOR
ABOVE TA = 25°C
5.8 mW/°C
7.6 mW/°C
11.0 mW/°C
11.0 mW/°C
9.2 mW/°C
8.0 mW/°C
4.2 mW/°C
TA = 70°C
POWER RATING
464 mW
608 mW
880 mW
880 mW
736 mW
640 mW
336 mW
5.6 mW/°C
448 mW
TA = 85°C
POWER RATING
337 mW
494 mW
715 mW
715 mW
598 mW
520 mW
273 mW
364 mW
TA = 125°C
POWER RATING
145 mW
190 mW
275 mW
275 mW
230 mW
200 mW
105 mW
—
recommended operating conditions
Supply voltage, VDD ±
Input voltage range, VI
Common-mode input voltage, VIC
Operating free-air temperature, TA
C SUFFIX
MIN
MAX
± 2.2
±8
VDD –
VDD –
0
VDD + – 1.5
VDD + – 1.5
70
I SUFFIX
MIN
MAX
± 2.2
±8
VDD –
VDD –
– 40
VDD + – 1.5
VDD + – 1.5
85
Q SUFFIX
MIN
MAX
± 2.2
±8
VDD –
VDD –
– 40
VDD + – 1.5
VDD + – 1.5
125
M SUFFIX
MIN
MAX
± 2.2
±8
VDD –
VDD –
– 55
VDD + – 1.5
VDD + – 1.5
125
UNIT
V
V
V
°C
4
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265