TLC2274C electrical characteristics at specified free-air temperature, VDD± = ±5 V (unless
otherwise noted)
PARAMETER
VIO Input offset voltage
Temperature coefficient of input
αVIO offset voltage
TEST CONDITIONS
TA†
25°C
Full range
25°C
to 70°C
TLC2274C
MIN TYP MAX
300 2500
3000
2
TLC2274AC
MIN TYP MAX
300 950
1500
UNIT
µV
2
µV/°C
Input offset voltage long-term
drift (see Note 4)
VIC = 0, VO = 0,
RS = 50 Ω
IIO
Input offset current
IIB
Input bias current
25°C
25°C
Full range
25°C
Full range
Common-mode input
VICR voltage range
25°C
RS = 50 Ω, |VIO | ≤ 5 mV
Full range
Maximum positive peak output
VOM + voltage
IO = – 20 µA
IO = – 200 µA
IO = – 1 mA
VIC = 0, IO = 50 µA
25°C
25°C
Full range
25°C
Full range
25°C
VOM –
Maximum negative peak output
voltage
VIC = 0,
IO = 500 µA
25°C
Full range
VIC = 0, IO = – 5 mA
AVD
Large-signal differential voltage
amplification
VO = ± 4 V RL = 10 kΩ
RL = 1 MΩ
rid
Differential input resistance
ri
Common-mode input resistance
ci
Common-mode input
capacitance
f = 10 kHz, N package
zo
Closed-loop output impedance
CMRR Common-mode rejection ratio
f = 1 MHz, AV = 10
VIC = – 5 V to 2.7 V,
VO = 0,
RS = 50 Ω
Supply-voltage rejection ratio
kSVR (∆VDD ± /∆VIO)
VDD ± = ± 2.2 V to ± 8 V,
VIC = 0, No load
25°C
Full range
25°C
Full range
25°C
25°C
25°C
25°C
25°C
25°C
Full range
25°C
Full range
0.002
0.5
1
–5
to
4
–5
to
3.5
4.85
4.85
4.25
4.25
– 4.8
5
– 4.8
5
– 3.5
– 3.5
25
25
– 5.3
to
4.2
4.99
4.93
4.65
– 4.9
9
– 4.9
1
– 4.1
50
300
1012
1012
8
130
75 80
75
80 95
80
0.002
0.5
100
1
100
– 5 – 5.3
to
to
4 4.2
–5
to
3.5
4.99
4.85 4.93
4.85
4.25 4.65
4.25
– 4.9
9
– 4.8 – 4.9
5
1
– 4.8
5
– 3.5 – 4.1
– 3.5
25 50
25
300
1012
1012
8
130
75 80
75
80 95
80
µV/mo
pA
100
pA
100
V
V
V
V/mV
Ω
Ω
pF
Ω
dB
dB
IDD Supply current
VO = 0,
No load
25°C
Full range
4.8
6
6
4.8
6
mA
6
† Full range is 0°C to 70°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265