|
TLC2274ACPW Datasheet, PDF (11/52 Pages) Texas Instruments – Advanced LinCMOSE RAIL-TO-RAIL OPERATIONAL AMPLIFIERS | |||
|
◁ |
TLC227x, TLC227xA
Advanced LinCMOS⢠RAIL-TO-RAIL
OPERATIONAL AMPLIFIERS
SLOS190B â FEBRUARY 1997 â REVISED JULY 1999
TLC2274C electrical characteristics at specified free-air temperature, VDD± = ±5 V (unless
otherwise noted)
PARAMETER
VIO Input offset voltage
Temperature coefficient of input
αVIO offset voltage
TEST CONDITIONS
TAâ
25°C
Full range
25°C
to 70°C
TLC2274C
MIN TYP MAX
300 2500
3000
2
TLC2274AC
MIN TYP MAX
300 950
1500
UNIT
µV
2
µV/°C
Input offset voltage long-term
drift (see Note 4)
VIC = 0, VO = 0,
RS = 50 â¦
IIO
Input offset current
IIB
Input bias current
25°C
25°C
Full range
25°C
Full range
Common-mode input
VICR voltage range
25°C
RS = 50 â¦, |VIO | ⤠5 mV
Full range
Maximum positive peak output
VOM + voltage
IO = â 20 µA
IO = â 200 µA
IO = â 1 mA
VIC = 0, IO = 50 µA
25°C
25°C
Full range
25°C
Full range
25°C
VOM â
Maximum negative peak output
voltage
VIC = 0,
IO = 500 µA
25°C
Full range
VIC = 0, IO = â 5 mA
AVD
Large-signal differential voltage
amplification
VO = ± 4 V RL = 10 kâ¦
RL = 1 Mâ¦
rid
Differential input resistance
ri
Common-mode input resistance
ci
Common-mode input
capacitance
f = 10 kHz, N package
zo
Closed-loop output impedance
CMRR Common-mode rejection ratio
f = 1 MHz, AV = 10
VIC = â 5 V to 2.7 V,
VO = 0,
RS = 50 â¦
Supply-voltage rejection ratio
kSVR (âVDD ± /âVIO)
VDD ± = ± 2.2 V to ± 8 V,
VIC = 0, No load
25°C
Full range
25°C
Full range
25°C
25°C
25°C
25°C
25°C
25°C
Full range
25°C
Full range
0.002
0.5
1
â5
to
4
â5
to
3.5
4.85
4.85
4.25
4.25
â 4.8
5
â 4.8
5
â 3.5
â 3.5
25
25
â 5.3
to
4.2
4.99
4.93
4.65
â 4.9
9
â 4.9
1
â 4.1
50
300
1012
1012
8
130
75 80
75
80 95
80
0.002
0.5
100
1
100
â 5 â 5.3
to
to
4 4.2
â5
to
3.5
4.99
4.85 4.93
4.85
4.25 4.65
4.25
â 4.9
9
â 4.8 â 4.9
5
1
â 4.8
5
â 3.5 â 4.1
â 3.5
25 50
25
300
1012
1012
8
130
75 80
75
80 95
80
µV/mo
pA
100
pA
100
V
V
V
V/mV
â¦
â¦
pF
â¦
dB
dB
IDD Supply current
VO = 0,
No load
25°C
Full range
4.8
6
6
4.8
6
mA
6
â Full range is 0°C to 70°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
11
|
▷ |