English
Language : 

TLC2274ACPW Datasheet, PDF (15/52 Pages) Texas Instruments – Advanced LinCMOSE RAIL-TO-RAIL OPERATIONAL AMPLIFIERS
TLC227x, TLC227xA
Advanced LinCMOS™ RAIL-TO-RAIL
OPERATIONAL AMPLIFIERS
SLOS190B – FEBRUARY 1997 – REVISED JULY 1999
TLC2272I electrical characteristics at specified free-air temperature, VDD± = ±5 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TA†
TLC2272I
MIN TYP MAX
TLC2272AI
UNIT
MIN TYP MAX
VIO Input offset voltage
25°C
Full range
300 2500
3000
300 950
µV
1500
αVIO
Temperature coefficient
of input offset voltage
25°C
to 85°C
2
2
µV/°C
Input offset voltage
long-term drift
(see Note 4)
VIC = 0,
RS = 50 Ω
VO = 0,
25°C
0.002
0.002
µV/mo
IIO
Input offset current
25°C
Full range
0.5
150
0.5
pA
150
IIB
Input bias current
25°C
Full range
1
150
1
pA
150
– 5 – 5.3
– 5 – 5.3
25°C
to
to
to
to
Common-mode input
VICR voltage range
RS = 50 Ω,
|VIO | ≤ 5 mV
4 4.2
4 4.2
V
–5
–5
Full range
to
to
3.5
3.5
IO = – 20 µA
VOM +
Maximum positive peak
output voltage
IO = – 200 µA
IO = – 1 mA
25°C
4.99
4.99
25°C
4.85 4.93
4.85 4.93
Full range 4.85
4.85
V
25°C
4.25 4.65
4.25 4.65
Full range 4.25
4.25
VIC = 0,
IO = 50 µA
25°C
– 4.99
– 4.99
25°C – 4.85 – 4.91
– 4.85 – 4.91
VOM –
Maximum negative
peak output voltage
VIC = 0,
IO = 500 µA Full range – 4.85
– 4.85
V
VIC = 0,
m IO = 5 A
25°C
Full range
– 3.5 – 4.1
– 3.5
– 3.5 – 4.1
– 3.5
Large-signal
AVD differential voltage
amplification
rid
Differential input
resistance
VO = ± 4 V
RL = 10 kΩ
RL = 1 mΩ
25°C
Full range
25°C
25°C
25
50
25
300
1012
25
50
25
300
1012
V/mV
Ω
ri
Common-mode input
resistance
25°C
1012
1012
Ω
ci
Common-mode input
capacitance
f = 10 kHz,
P package
25°C
8
8
pF
zo
Closed-loop output
impedance
f = 1 MHz,
AV = 10
25°C
130
130
Ω
Common-mode
CMRR rejection ratio
VIC = 0 to 2.7 V,
25°C
75
80
VO = 2.5 V,
RS = 50 Ω Full range
75
75
80
dB
75
kSVR
Supply-voltage
rejection ratio
(∆VDD ± /∆VIO)
VDD = 4.4 V to 16 V,
VIC = VDD /2, No load
25°C
80
95
Full range
80
80
95
dB
80
IDD Supply current
VO = 2.5 V,
No load
25°C
Full range
2.4
3
3
2.4
3
mA
3
† Full range is – 40°C to 85°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265