English
Language : 

SN74ALVCH16831 Datasheet, PDF (4/9 Pages) Texas Instruments – 1-TO-4 ADDRESS REGISTER/DRIVER WITH 3-STATE OUTPUTS
SN74ALVCH16831
1-TO-4 ADDRESS REGISTER/DRIVER
WITH 3-STATE OUTPUTS
SCES083F – AUGUST 1996 – REVISED SEPTEMBER 2004
www.ti.com
ELECTRICAL CHARACTERISTICS
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
VOH
IOH = -100 µA
IOH = -4 mA
IOH = -6 mA
TEST CONDITIONS
IOH = -12 mA
VCC
1.65 V to 3.6 V
1.65 V
2.3 V
2.3 V
2.7 V
3V
MIN
VCC - 0.2
1.2
2
1.7
2.2
2.4
TYP (1)
MAX UNIT
V
IOH = -24 mA
IOL = 100 µA
IOL = 4 mA
VOL
IOL = 6 mA
IOL = 12 mA
3V
2
1.65 V to 3.6 V
1.65 V
2.3 V
2.3 V
2.7 V
0.2
0.45
0.4
V
0.7
0.4
II
II(hold)
IOZ
ICC
∆ICC
Ci
Control inputs
Data Inputs
IOL = 24 mA
VI = VCC or GND
VI = 0.58 V
VI = 1.07 V
VI = 0.7 V
VI = 1.7 V
VI = 0.8 V
VI = 2 V
VI = 0 to 3.6 V(2)
VO = VCC or GND
VI = VCC or GND, IO = 0
One input at VCC - 0.6 V, Other inputs at VCC or GND
VI = VCC or GND
3V
3.6 V
1.65 V
1.65 V
2.3 V
2.3 V
3V
3V
3.6 V
3.6 V
3.6 V
3 V to 3.6 V
3.3 V
0.55
±5 µA
25
-25
45
-45
µA
75
-75
±500
±10 µA
40 µA
750 µA
4.5
pF
5
Co
Outputs
VO = VCC or GND
3.3 V
7.5
pF
(1) All typical values are at VCC = 3.3 V, TA = 25°C.
(2) This is the bus-hold maximum dynamic current. It is the minimum overdrive current required to switch the input from one state to
another.
TIMING REQUIREMENTS
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 1)
fclock
tw
tsu
th
Clock frequency
Pulse duration, CLK high or low
Setup time, A data before CLK↑
Hold time, A data after CLK↑
VCC = 1.8 V
MIN MAX
(1)
(1)
(1)
(1)
VCC = 2.5 V
± 0.2 V
MIN MAX
150
3.3
2
0.7
VCC = 2.7 V
MIN MAX
150
3.3
2
0.5
(1) This information was not available at the time of publication.
VCC = 3.3 V
± 0.3 V
MIN MAX
150
3.3
1.6
1.1
UNIT
MHz
ns
ns
ns
4