TLC8188 Datasheet, PDF (3/12 Pages) Texas Instruments – 10-BIT, 4 MSPS, CIS/LINEAR CCD SENSOR PROCESSOR
TLC8188
10-BIT, 4 MSPS, CIS/LINEAR CCD SENSOR PROCESSOR
SLAS177A – DECEMBER 1997 – REVISED SEPTEMBER 1998
Terminal Functions
TERMINAL
NAME
NO.
ADCCLK
15
AGND
26
AVDD
27
BIN
28
CLAMP
25
DGND
14
DIGND
7
DIVDD
6
DVDD
13
GIN
29
MA1, MA0/ACYC 21, 22
NRESET
19
OE
OP(0–4)
OP(5–9)
RIN
RMO
RPO
SCK/RNW
SDI/DNA
SEN/STB
SR
SV
20
1–5
8 – 12
30
31
32
16
17
18
24
23
I/O DESCRIPTION
I ADC conversion clock input.
Analog ground
Analog supply voltage, 5 V
I Blue channel input
I CCD input clamp signal, active high
Digital ground
Digital interface circuit ground
Digital interface circuit supply voltage, 3 V to 5 V
Digital supply voltage, 5 V
I Green channel input
I MA1 and MA0 select the color to which all internal MUX (input, gain, offset) will point. When in
auto-cycling mode, the input mux and internal registers are auto-cycled by the ACYC. The ACYC is a
control signal such as a line start pulse that defines the start of a current scanning line.
I Power-on reset and Interface mode control. If SEN/STB is 1 when NRESET goes high then the device
is in parallel configuration data input mode. If SEN/STB is 0 when NRESET goes high then the device
is in serial data input mode.
I Three-state output enable, active low
I/O Three-state bi-directional data bus, OP0 and OP1 are output only.
I/O Three-state bi-directional data bus.
I Red channel input
O Ref– output for external decoupling
O Ref+ output for external decoupling
I Serial interface: serial clock
Parallel interface: 1 – OP(9–2) is output bus, 0 – OP(9–2) is input bus
I Serial interface: serial interface input data
Parallel interface: 1 – data, 0 – address
I Serial interface: serial data transfer enable, active high.
Parallel interface: strobe, active low.
I CCD reset level sample pulse input
I CCD signal level sample pulse input
absolute maximum ratings over operating free-air temperature (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 6.5 V
Analog input voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to VCC+0.3 V
Reference input voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VCC+0.3 V
Digital input voltage range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to VCC+0.3 V
Operating virtual junction temperature range, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –40°C to 150°C
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265