TLE202XA Datasheet, PDF (22/79 Pages) Texas Instruments – EXCALIBUR HIGH-SPEED LOW-POWER PRECISION OPERATIONAL AMPLIFIERS
TLE2021 electrical characteristics at specified free-air temperature, VCC = ±15 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TA†
TLE2021M
MIN TYP MAX
TLE2021AM
MIN TYP MAX
TLE2021BM
UNIT
MIN TYP MAX
VIO
Input offset voltage
25°C
Full range
120 500
1000
80 200
500
40 100
µV
200
αVIO
Temperature coefficient of
input offset voltage
Full range
2
2
2
µV/°C
Input offset voltage long-term
drift (see Note 4)
VIC = 0,
RS = 50 Ω
25°C
0.006
0.006
0.006
µV/mo
IIO
Input offset current
25°C
Full range
0.2
6
10
0.2
6
10
0.2
6
nA
10
IIB
Input bias current
25°C
Full range
25
70
90
25
70
90
25
70
nA
90
VICR
Common-mode input
voltage range
RS = 50 Ω
– 15 – 15.3
– 15 – 15.3
– 15 – 15.3
25°C
to
to
to
to
to
to
13.5
14
13.5
14
13.5
14
V
– 15
– 15
–15
Full range
to
to
to
13.2
13.2
13.2
VOM +
Maximum positive peak
output voltage swing
VOM –
Maximum negative peak
output voltage swing
RL = 10 kΩ
25°C
14 14.3
14 14.3
14 14.3
V
Full range 13.8
13.8
13.8
25°C – 13.7 – 14.1
– 13.7 – 14.1
– 13.7 – 14.1
V
Full range – 13.6
– 13.6
– 13.6
AVD
Large-signal differential
voltage amplification
VO = ± 10 V,
25°C
1 6.5
RL = 10 kΩ Full range
0.5
1 6.5
0.5
1 6.5
0.5
V/µV
25°C
100 115
100 115
100 115
CMRR Common-mode rejection ratio VIC = VICRmin, RS = 50 Ω
Full range
96
96
dB
96
Supply-voltage rejection ratio
25°C
105 120
105 120
105 120
kSVR (∆VCC ± /∆VIO)
VCC ± = ± 2.5 V to ± 15 V
Full range 100
100
100
dB
ICC
∆ICC
Supply current
Supply current change over
operating temperature range
VO = 0,
No load
25°C
Full range
Full range
200 300
300
10
200 300
300
10
200 300
µA
300
10
µA
† Full range is – 55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated to TA = 25°C using the Arrhenius equation
and assuming an activation energy of 0.96 eV.