English
Language : 

TLE202XA Datasheet, PDF (17/79 Pages) Texas Instruments – EXCALIBUR HIGH-SPEED LOW-POWER PRECISION OPERATIONAL AMPLIFIERS
TLE2022 electrical characteristics at specified free-air temperature, VCC = 5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TA†
TLE2022I
MIN TYP MAX
TLE2022AI
MIN TYP MAX
TLE2022BI
UNIT
MIN TYP MAX
VIO
Input offset voltage
25°C
Full range
600
400
250
µV
800
550
400
αVIO
Temperature coefficient of
input offset voltage
Full range
2
2
2
µV/°C
Input offset voltage long-term
drift (see Note 4)
VIC = 0,
RS = 50 Ω
25°C
0.005
0.005
0.005
µV/mo
IIO
Input offset current
25°C
Full range
0.5
6
10
0.4
6
10
0.3
6
nA
10
IIB
Input bias current
25°C
Full range
35
70
90
33
70
90
30
70
nA
90
VICR
Common-mode input
voltage range
RS = 50 Ω
0 – 0.3
0 – 0.3
0 – 0.3
25°C
to
to
to
to
to
to
3.5
4
3.5
4
3.5
4
V
0
0
0
Full range
to
to
to
3.2
3.2
3.2
VOH High-level output voltage
VOL
Low-level output voltage
RL = 10 kΩ
25°C
Full range
25°C
Full range
4 4.3
4 4.3
4 4.3
V
3.9
3.9
3.9
0.7 0.8
0.9
0.7 0.8
0.9
0.7 0.8
V
0.9
AVD
Large-signal differential
voltage amplification
25°C
VO = 1.4 V to 4 V, RL = 10 kΩ Full range
0.3 1.5
0.2
0.4 1.5
0.2
0.5 1.5
0.2
V/µV
CMRR Common-mode rejection ratio VIC = VICRmin,
RS = 50 Ω
25°C
Full range
85 100
80
87 102
82
90 105
dB
85
kSVR
ICC
∆ICC
Supply-voltage rejection ratio
(∆VCC ± /∆VIO)
VCC = 5 V to 30 V
Supply current
Supply current change over
operating temperature range
VO = 2.5 V,
No load
25°C
Full range
25°C
Full range
Full range
100 115
103 118
105 120
dB
95
98
100
450 600
600
450 600
600
450 600
µA
600
15
15
15
µA
† Full range is – 40°C to 85°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated to TA = 25°C using the Arrhenius equation
and assuming an activation energy of 0.96 eV.