TLE202XA Datasheet, PDF (21/79 Pages) Texas Instruments – EXCALIBUR HIGH-SPEED LOW-POWER PRECISION OPERATIONAL AMPLIFIERS
TLE2021 electrical characteristics at specified free-air temperature, VCC = 5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TLE2021M
TLE2021AM
TLE2021BM
TA†
UNIT
MIN TYP MAX MIN TYP MAX MIN TYP MAX
VIO
Input offset voltage
25°C
Full range
120 600
1100
100 300
600
80 200
µV
300
αVIO
Temperature coefficient of
input offset voltage
Full range
2
2
2
µV/°C
Input offset voltage long-term
drift (see Note 4)
VIC = 0,
RS = 50 Ω
25°C
0.005
0.005
0.005
µV/mo
IIO
Input offset current
25°C
Full range
0.2
6
10
0.2
6
10
0.2
6
nA
10
IIB
Input bias current
25°C
Full range
25
70
90
25
70
90
25
70
nA
90
VICR
Common-mode input
voltage range
RS = 50 Ω
0 – 0.3
0 – 0.3
0 – 0.3
25°C
to
to
to
to
to
to
3.5
4
3.5
4
3.5
4
V
0
0
0
Full range
to
to
to
3.2
3.2
3.2
VOH High-level output voltage
VOL Low-level output voltage
RL = 10 kΩ
25°C
4 4.3
4 4.3
4 4.3
V
Full range 3.8
3.8
3.8
25°C
Full range
0.7 0.8
0.95
0.7 0.8
0.95
0.7 0.8
V
0.95
AVD
Large-signal differential
voltage amplification
25°C
0.3 1.5
VO = 1.4 V to 4 V, RL = 10 kΩ Full range
0.1
0.3 1.5
0.1
0.3 1.5
0.1
V/µV
CMRR Common-mode rejection ratio VIC = VICRmin, RS = 50 Ω
25°C
Full range
85 110
80
85 110
80
85 110
dB
80
kSVR
Supply-voltage rejection ratio
(∆VCC ± /∆VIO)
VCC = 5 V to 30 V
25°C
105 120
105 120
105 120
dB
Full range 100
100
100
ICC
∆ICC
Supply current
Supply current change over
operating temperature range
VO = 2.5 V,
No load
25°C
Full range
Full range
170 230
230
9
170 230
230
9
170 230
µA
230
9
µA
† Full range is – 55°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated to TA = 25°C using the Arrhenius equation
and assuming an activation energy of 0.96 eV.