English
Language : 

DLPC350 Datasheet, PDF (20/50 Pages) Texas Instruments – DLP Digital Controller for the DLP4500 DMD
DLPC350
DLPS029A – APRIL 2013 – REVISED MAY 2013
www.ti.com
ABSOLUTE MAXIMUM RATING
over operating free-air temperature range (unless otherwise noted). Stresses beyond those listed under Absolute Maximum
Ratings may cause permanent damage to the device. The Absolute Maximum Ratings are stress ratings only, and functional
performance of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to Absolute Maximum Rated conditions for extended periods may affect device reliability.
PARAMETER
CONDITIONS
MIN MAX UNIT
Electrical
Supply Voltage(1)(2)
VDDC (Core 1.2V Power)
–0.5
1.7 V
VDD33
–0.5
3.8 V
VDD_DMD
-0.5
2.3 V
VDD12_FPD
-0.5
1.7 V
VDD33_FPD
-0.5
3.8 V
VDD12_PLLD
-0.5
1.7 V
VDD12_PLLM
-0.5
1.7 V
VDD_18_PLLD
-0.5
2.3 V
Input Voltage (VI)(3)
VDD_18_PLLM
USB
OSC
-0.5
-1.00
-0.3
2.3 V
5.25 V
3.6 V
LVCMOS
I2C
-0.5
3.6 V
-0.5
3.6 V
LVDS
-0.5
3.6 V
Output Voltage (VO)
USB
DMD LPDDR
-1.00
-0.3
5.25 V
2.0 V
LVCMOS
I2C
-0.5
3.6 V
-0.5
3.6 V
Environmental
TJ
Tstg
ESD (4)
Junction temperature
Storage temperature
Electrostatic discharge immunity
Human Body Model (VESDHBM)
Charged Device Model (VESDCDM)
Machine Model (VESD MM)
0
105 ºC
-40
125 ºC
±2000 V
±500
±150
(1) All voltages referenced to VSS (ground).
(2) All of the 3.3V, 1.9V, 1.8V, and 1.2V power should be applied and removed per the procedure defined in System Power and Reset.
(3) Applies to external input and bidirectional buffers.
(4) Tested in accordance with JESD22-A114-B Electrostatic Discharge (ESD) sensitivity testing Human Body Model (HBM).
20
Submit Documentation Feedback
Product Folder Links: DLPC350
Copyright © 2013, Texas Instruments Incorporated