www.ti.com
These devices have limited built-in ESD protection. The leads should be shorted together or the device
placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates.
DESCRIPTION (Continued)
The communications interface allows the host to observe and control the current status of the bq29312A. It
enables cell balancing, enters different power modes, sets overload levels, sets the overload blanking delay time,
sets short-circuit threshold levels for charge and discharge, and sets the short-circuit blanking delay time.
Cell balancing of each cell is performed via a cell bypass path, which is enabled via the internal control register
accessible via the I2C compatible interface. The maximum bypass current is set via an external series resistor
and internal FET on resistance (typical 400 Ω).
ORDERING INFORMATION(1)
TA
–40°C to 85°C
TSSOP (PW)(2)
bq29312APWR-SA
PACKAGED
QFN (RTH) (3)
bq29312ARTH
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
website at www.ti.com.
(2) The bq29312A can be ordered in tape and reel by adding the suffix R to the orderable part number, ie: bq29312APWR bq29312ARTHR.
(3) The QFN package is also made available in mini reel, add suffix T to the orderable part number, ie: bq29312ARTHT.
PACKAGE DISSIPATION RATINGS
PACKAGE
PW
POWER RATING
TA ≤ 25°C
874 mW
DERATING FACTOR
ABOVE TA ≤ 25°C
6.99 W/°C
POWER RATING
TA ≤ 70°C
559 mW
TA = 85°C
454 mW
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range unless otherwise noted(1)(2)
VCC
Supply voltage range
PACK, BAT
VC1, VC2, VC3, VC4
SR1, SR2
VI
Input voltage range
VC5
VC1 to VC2, VC2 to VC3, VC3 to VC4, VC4 to
VC5
WDI, SLEEP, SCLK, SDATA
ZVCHG
DSG, CHG
VO
Output voltage range
OD
PMS
TOUT, SCLK, SDATA, CELL, XALERT
Current for cell balancing
Continuous total power dissipation
Tstg
Storage temperature range
Lead temperature (soldering, 10 s)
bq29312A
–0.3 V to 34 V
–0.3 V to 34 V
–1.0 V to 1.0 V
–1.0 V to 4.0 V
–0.3 to 8.5 V
–0.3 to 8.5 V
–0.3 V to 34 V
–0.3 V to BAT
–0.3 V to 34 V
–0.3 V to PACK–0.2 V
–0.3 to 7 V
10 mA
See Dissipation Rating Table
–65°C to 150°C
300°C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to ground of this device except VCn–VC(n+1), where n = 1-, 2-, 3-, 4-cell voltage.
2