Table 7-56. Switching Characteristics for Host-Port Interface Cycles(1)(2)
(see Table 7-56 through Figure 7-51)
www.ti.com
NO.
PARAMETER
-720
-850
-1000
MIN
MAX
Case 1. HPIC or HPIA read
5
15
1
td(HSTBL-HDV)
Delay time, HSTROBE low to
DSP data valid
Case 2. HPID read with no
auto-increment (3)
Case 3. HPID read with auto-increment
and read FIFO initially empty(3)
9 * M + 20
9 * M + 20
Case 4. HPID read with auto-increment
and data previously prefetched into the
5
15
read FIFO
2
tdis(HSTBH-HDV)
Disable time, HD high-impedance from HSTROBE high
3
ten(HSTBL-HD)
Enable time, HD driven from HSTROBE low
4
td(HSTBL-HRDYH)
Delay time, HSTROBE low to HRDY high
5
td(HSTBH-HRDYH) Delay time, HSTROBE high to HRDY high
Case 1. HPID read with no
6
td(HSTBL-HRDYL)
Delay time, HSTROBE low to auto-increment(3)
HRDY low
Case 2. HPID read with auto-increment
and read FIFO initially empty(3)
1
4
3
15
12
12
10 * M + 20
10 * M + 20
7
td(HDV-HRDYL)
34
td(DSH-HRDYL)
Delay time, HD valid to HRDY low
Case 1. HPIA write(3)
Delay time, HSTROBE high to
HRDY low
Case 2. HPID write with no
auto-increment (3)
0
5 * M + 20
5 * M + 20
35
td(HSTBL-HRDYL)
Delay time, HSTROBE low to HRDY low for HPIA write and FIFO not
empty (3)
40 * M + 20
36
td(HASL-HRDYH)
Delay time, HAS low to HRDY high
12
(1) M = SYSCLK3 period = 6/CPU clock frequency in ns. For example, when running parts at 1000 MHz, use M = 6 ns.
(2) HSTROBE refers to the following logical operation on HCS, HDS1, and HDS2: [NOT(HDS1 XOR HDS2)] OR HCS.
(3) Assumes the HPI is accessing L2/L1 memory and no other master is accessing the same memory location.
UNIT
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
168 C64x+ Peripheral Information and Electrical Specifications
Submit Documentation Feedback