English
Language : 

TC213 Datasheet, PDF (15/21 Pages) Texas Instruments – 1024- × 512-pixel ccd image sensor
TC213
1024- × 512-PIXEL CCD IMAGE SENSOR
SOCS013B – AUGUST 1989 – REVISED DECEMBER 1991
optical characteristics, TA = 25°C, integration time = 33 ms (unless otherwise noted)
PARAMETER
MIN
TYP MAX UNIT
Sensitivity (see Note 9)
No IR filter
With IR filter
Measured at VU
(see Note 10)
518
mV/lx
64
Saturation signal, Vsat (see Note 11)
Maximum usable signal, Vuse
Blooming overload ratio (see Note 12)
Image-area well capacity
320
200
100
60 x 103
mV
mV
electrons
Smear (see Note 13)
Dark current
Dark signal (see Note 14)
TA = 40°C
TA = 21°C
TC213-30
TC213-40
0.027
0.0016
5
5
nA/cm2
mV
Pixel uniformity
TC213-30
TC213-40
8
mV
12
Column uniformity
TC213-30
TC213-40
1.4
mV
1.4
Shading
VO = 1/2 VU (see Note 10)
15%
NOTES: 9. Sensitivity is measured at an integration time of 33 ms with a source temperature of 2859 K. A CM-500 filter is used. Sensitivity is
measured at any illumination level that gives an output voltage level less than VU.
10. VU is the output voltage that represents the threshold of operation of antiblooming. VU ≈ 1/2 saturation signal.
11. Saturation is the condition in which further increase in exposure does not lead to further increase in output signal.
12. Blooming is the condition in which charge is induced in an element by light incident on another element. Blooming overload ratio
is the ratio of blooming exposure to saturation exposure.
13. Smear is the measure of error induced by transferring charge through an illuminated pixel in shutterless operation. It is equivalent
to the ratio of the single-pixel transfer time during a fast dump to the exposure time using an illuminated section that is 1/10 of the
image area vertical height with recommended clock frequencies. Exposure time is 33 ms, the fast dump clocking rate during vertical
timing is 1 MHz, and the illuminated section is 1/10 of the height of the image section.
14. Dark-signal level is measured from the dark dummy pixels.
timing requirements
tr
Rise time
tf
Fall time
IAG
SRG
SAG
TRG
ABGI, ABGS
RST1, RST2
IAG
SRG
SAG
TRB
ABGI, ABGS
RST1, RST2
MIN MAX UNIT
200
10
200
ns
200
100
10
200
10
200
ns
200
100
10
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265