English
Language : 

TLC220X Datasheet, PDF (12/62 Pages) Texas Instruments – Advanced LinCMOSE LOW-NOISE PRECISION OPERATIONAL AMPLIFIERS
TLC220x, TLC220xA, TLC220xB, TLC220xY
Advanced LinCMOS™ LOW-NOISE PRECISION
OPERATIONAL AMPLIFIERS
SLOS175 – FEBRUARY 1997
TLC2201C electrical characteristics at specified free-air temperature, VDD = 5 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TA†
TLC2201AC
TLC2201BC
UNIT
MIN TYP MAX MIN TYP MAX
VIO Input offset voltage
25°C
Full range
80 200
300
80 200
µV
300
αVIO
Temperature coefficient of
input offset voltage
Full range
0.5
0.5
µV/°C
Input offset voltage long-term
drift (see Note 4)
VIC = 0,
RS = 50 Ω
25°C
0.001 0.005
0.001 0.005 µV/mo
IIO
Input offset current
25°C
Full range
0.5
100
0.5
pA
100
IIB
Input bias current
25°C
Full range
1
100
1
pA
100
VICR
Common-mode input voltage
range
RS = 50 Ω
Full range
0 to
2.7
0 to
2.7
V
VOH
Maximum high-level output
voltage
RL = 10 kΩ
25°C
4.7 4.8
4.7 4.8
V
Full range 4.7
4.7
VOL
Maximum low-level output
voltage
IO = 0
25°C
Full range
0 50
50
0 50
mV
50
AVD
Large-signal differential
voltage amplification
VO = 1 V to 4 V,
RL = 500 kΩ
VO = 1 V to 4 V,
RL = 10 kΩ
25°C
150 315
Full range 100
25°C
25 55
Full range 15
150 315
100
25 55
15
V/mV
CMRR Common-mode rejection ratio
VIC = VICRmin,
25°C
VO = 0,
RS = 50 Ω Full range
90 110
85
90 110
dB
85
kSVR
Supply voltage rejection ratio
(∆VDD ± /∆VIO)
VDD = 4.6 V to 16 V
25°C
Full range
90 110
85
90 110
dB
85
IDD Supply current
VO = 2.5 V, No load
25°C
Full range
1 1.5
1.5
1 1.5
mA
1.5
† Full range is 0°C to 70°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150 °C extrapolated
to TA = 25 °C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
12