English
Language : 

TIBPAL22V10-7C Datasheet, PDF (12/17 Pages) Texas Instruments – HIGH-PERFORMANCE IMPACT-X E PROGRAMMABLE ARRAY LOGIC CIRCUITS
TIBPAL22V10-7C
HIGH-PERFORMANCE IMPACT-X ™ PROGRAMMABLE ARRAY LOGIC CIRCUITS
SRPS014D – D3520, AUGUST 1990 – REVISED NOVEMBER 1995
THERMAL INFORMATION
thermal management of the TIBPAL22V10-7C
Thermal management of the TIBPAL22V10-7CNT and TIBPAL22V10-7CFN is necessary when operating at
certain conditions of frequency, output loading, and outputs switching simultaneously. The device and system
application will determine the appropriate level of management.
Determining the level of thermal management is based on factors such as power dissipation (PD), ambient
temperature (TA ), and transverse airflow (FPM). Figures 4 (a) and 4 (b) show the relationship between ambient
temperature and transverse airflow at given power dissipation levels. The required transverse airflow can be
determined at a particular ambient temperature and device power dissipation level in order to ensure the device
specifications.
Figure 5 illustrates how power dissipation varies as a function of frequency and the number of outputs switching
simultaneously. It should be noted that all outputs are fully loaded (CL = 50 pF ). Since the condition of ten fully
loaded outputs represents the worst-case condition, each application must be evaluated accordingly.
MINIMUM TRANSVERSE AIR FLOW
vs
AMBIENT TEMPERATURE
600
MINIMUM TRANSVERSE AIR FLOW
vs
AMBIENT TEMPERATURE
600
500
500
400
PD = 1.8 W
300
PD = 1.6 W
PD = 1.4 W
PD = 1.2 W
PD = 1 W
200
100
400
300
PD = 1.8 W
PD = 1.6 W
200
PD = 1.4 W
PD = 1.2 W
PD = 1 W
100
0
0 10 20 30 40 50 60 70 80
TA – Ambient Temperature – °C
(a) TIBPAL22V10-7CNT
Figure 4
0
0 10 20 30 40 50 60 70 80
TA – Ambient Temperature – °C
(b) TIBPAL22V10-7CFN
12
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265