TC215 Datasheet, PDF (11/19 Pages) Texas Instruments – 1024- × 1024-PIXEL CCD IMAGE SENSOR | |||
|
◁ |
TC215
1024- Ã 1024-PIXEL CCD IMAGE SENSOR
SOCS014B â AUGUST 1989 â REVISED DECEMBER 1991
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)â
Supply voltage range for ADB, CDB, IDB, TDB (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 V to 15 V
Input voltage range for ABG1, ABG2, IAG1, IAG2, RST1, RST2, SRG1, SRG2, TRG . . . . . . â15 V to 15 V
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â10°C to 40°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â30°C to 85°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
â Stresses beyond those listed under âabsolute maximum ratingsâ may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under ârecommended operating conditionsâ is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to the substrate terminal.
recommended operating conditions
MIN NOM MAX UNIT
Supply voltage for ADB, CDB, IDB, TDB
11
12
13 V
Substrate bias voltage
0
V
IAG1, IAG2
High level
Low level
1.5
2 2.5
â11
â9
SRG1, SRG2
High level
Low level
1.5
2 2.5
â11
â9
Input voltage, VIâ¡
RST1, RST2
High level
Low level
High level
1.5
2 2.5
â11
â9 V
5 5.5
6
ABG1, ABG2
Intermediate level§
â1.5 â1. 2 â 0.9
Low level
â7.5 â7 â 6.5
TRG
High level
Low level
1.5
2 2.5
â11
â9
TRG, SRG1, SRG2, RST1, RST2
10
Clock frequency, fclock IAG1, IAG2
ABG1, ABG2
1 MHz
1
Capacitive load
OUT1, OUT2
8 pF
Operating free-air temperature, TA
â 10
40 °C
â¡ The algebraic convention, in which the least-positive (most negative) value is designated minimum, is used in this data sheet for clock voltage
levels.
§ Adjustment is required for optimal performance.
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
2-11
|
▷ |