English
Language : 

TIBPAL20L8-5C Datasheet, PDF (10/35 Pages) Texas Instruments – HIGH-PERFORMANCE IMPACT-X PAL CIRCUITS
TIBPAL20R4-5C, TIBPAL20R6-5C
HIGH-PERFORMANCE IMPACT-X ™ PAL® CIRCUITS
SRPS010F – D3353, OCTOBER 1989 – REVISED SEPTEMBER 1992
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, VCC (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Voltage applied to disabled output (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Operating free-air temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 75°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
NOTE 1: These ratings apply except for programming pins during a programming cycle or during a preload cycle.
recommended operating conditions
MIN NOM MAX UNIT
VCC
VIH
Supply voltage
High-level input voltage (see Note 2)
4.75
5 5.25 V
2
5.5 V
VIL
IOH
IOL
fclock
tw
Low-level input voltage (see Note 2)
High-level output current
Low-level output current
Clock frequency
Pulse duration, clock
High
Low
0.8 V
– 3.2 mA
24 mA
0
125 MHz
4
ns
4
tsu
Setup time, input or feedback before clock↑
th
Hold time, input or feedback after clock↑
TA
Operating free-air temperature
4.5
ns
0
ns
0
25
75 °C
NOTE 2: These are absolute voltage levels with respect to the ground pin of the device and include all overshoots due to system and/or tester
noise. Testing these parameters should not be attempted without suitable equipment.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily
include testing of all parameters.
10
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265