TC277 Datasheet, PDF (10/19 Pages) Texas Instruments – 735- × 580-PIXEL CCD IMAGE SENSOR | |||
|
◁ |
TC277
735- Ã 580-PIXEL CCD IMAGE SENSOR
SOCS020B â DECEMBER 1991
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)â
Supply voltage range, VCC: ADB, CDB, IDB, TDB (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 V to 15 V
Input voltage range, VI: ABG, IAG, SRG, SAG, TRG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â15 V to 15 V
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â 10°C to 45°C
Storage temperature range, TSTG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . â 30°C to 85°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
â Stresses beyond those listed under âabsolute maximum ratingsâ may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under ârecommended operating conditionsâ is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to the substrate terminal.
recommended operating conditions
MIN NOM MAX UNIT
Supply voltage, VCC
Substrate bias voltage
ADB, CDB, IDB, TDB
12
V
0
V
High level
1.5
2 2.5
IAG
Intermediate level§
â 5.7
Low level
â11
â9
SRG1, SRG2, SRG3
High level
Low level
1.5
2 2.5
â11
â9
Input voltage, VIâ¡
ABG
High level
Intermediate level§
2
4
â 2.3
6
V
Low level
â7
SAG
High level
Low level
1.5
2 2.5
â11
â9
TRG
High level
Low level
1.5
2 2.5
â11
â9
IAG, SAG
3.34
Clock frequency, fclock
SRG1, SRG2, SRG3, TRG
ABG
4.46 MHz
3.34
Load capacitance
OUT1, OUT2, OUT3
6 pF
Operating free-air temperature, TA
â10
45 °C
â¡ The algebraic convention, in which the least-positive (most negative) value is designated minimum, is used in this data sheet for clock voltage
levels.
§ Adjustment is required for optimal performance.
10
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
|
▷ |