English
Language : 

80C154 Datasheet, PDF (11/24 Pages) TEMIC Semiconductors – CMOS 0 to 36 MHz Single Chip 8-bit Microcontroller
32 Bit Counter
Figure 13 illustrates the 32 bit COUNTER mode.
Figure 12. 32 Bit Counter Configuration.
80C154/83C154
D In this mode, T32 = 0 and C/T0 = 1. Before it can
make an increment, the 83C154µ must detect two
transitions on its T0 input. As shown in figure 14,
Figure 13. Counter Incrementation Condition.
input T0 is sampled on each S5P2 state of every
machine cycle or, in other words, every OSC ÷ 12.
D The counter will only evolve if a level 1 is detected
during state S5P2 of cycle Ci and if a level 0 is
detected during state S5P2 of cycle Ci + n.
D Consequently, the minimal period of signal fEXT
admissible by the counter must be greater than or
equal to two machine cycles. The following formula
should be used to calculate the operating frequency.
f
+
fEXT
65536ć(T0,
Ă
T1)
fEXT
t
OSC
24
Figure 14. The Different Watchdog Configurations.
Watchdog Mode
D WDT = 1 enables access to this mode. As shown in
figure 15, all the modes of TIMERS 0 and 1, of which
the overflows act on TF1 (TF1 = 1), activate the
WATCHDOG Mode.
MATRA MHS
11