Filter and Moisture
Separator
Airflow
Regulator
Lubricator
To Machine
408-9393
Figure 3
4. INSTALLATION AND REMOVAL OF TERMINATING HEAD OR FEED TRACK ASSEMBLY
1. Disconnect the power bench assembly from the air supply.
DANGER
To avoid personal injury, always disconnect the power bench assembly from the air supply when installing or removing the
terminating head or feed track assembly.
2. Position the blade tip of a screwdriver between the shoulder of the key and the power assembly body.
Gently pry the key out of the keyway.
3. Insert the terminating head or feed track assembly into the head entrance of the power assembly
body until it bottoms. See Figure 4.
4. Insert the key completely into the keyway to retain the terminating head or feed track assembly.
5. To remove the terminating head or feed track assembly, disconnect the power bench assembly from
air supply, remove the key, and pull the terminating head or feed track assembly out of the power
assembly. Refer to Figure 4.
CAUTION
Do not use this tool as a blunt object, a crushing device, or for any purpose other than crimping the proper specified product.
Inappropriate use of the tool could result in personal injury or damage to the tool.
Key
Bench Mount
Terminating Head
Or Feed Track
Assembly Entrance
Connector
(Ref)
Wire (Ref)
Terminating
Head (Ref)
Connector
Advances in One
Direction Only
Terminating
Head (Ref)
Figure 4
5. OPERATION
The following procedure provides only general information concerning crimping. Refer to the instructions
packaged with the terminating heads for detailed information including wire stripping dimensions and
instructions for positioning terminals in the terminating heads.
1. Insert the connector into the left side of the head.
2. Align the contact to be terminated with the wire inserter of the head. Make sure that the locating pawl
rests between the connector index ribs.
Rev F