3. INSTALLATION
DANGER
To avoid personal injury, always disconnect handle assembly from the air supply when installing or removing the bench mount.
The bench mount is designed to be mounted in either of the two positions shown in Figure 2. Orientation of the
bench mount depends on operator preference and the desired eject direction of terminated connector (refer to
Figure 4). Install the bench mount as follows:
1. Place the bench mount on a bench or work table in the desired location and orientation.
2. Mark the location for the screws in the bench surface through the drilled holes of the bench mount
flange. Drill holes for the mounting screws.
NOTE
Mounting hardware is not supplied with the power bench assembly and must be supplied by the customer.
Air Tube to
Foot Switch
Terminating Head (Ref)
Pneumatic Power
Assembly
Bench
Mount
Key
Terminating Head
(Ref)
Bench or
Work Table
Mounting Hardware
(Customer Supplied)
Air Tube to
Foot Switch
Figure 2
3. Secure the screws.
4. Connect the air tube to an approved air source. It is recommended that a filter-regulator-lubricator unit
with the lubricator adjusted to the minimum setting be used with the power bench assembly. Refer to
Figure 3.
DANGER
If not using quick-disconnect fittings to connect the tool to the air supply, provide operators other means to easily disconnect
the tool from the air supply. Such as a pneumatic lock-out on the air line that bleeds air after it is turned off.
NOTE
The power assembly is designed to operate at an air pressure range of 276 through 483 kPa [40 through 70 psi]. Service life of
the power assembly can be greatly extended when only the necessary air pressure is applied. Excessive pressure causes
unnecessary wear and strain on the power assembly, terminating head or feed track assembly, and connectors.
Rev F
3 of 6