English
Language : 

LPS001WP Datasheet, PDF (9/30 Pages) STMicroelectronics – MEMS pressure sensor 300-1100 mbar absolute digital output barometer
LPS001WP
3
Absolute maximum ratings
Absolute maximum ratings
Stress above those listed as “Absolute maximum ratings” may cause permanent damage to
the device. This is a stress rating only and functional operation of the device under these
conditions is not implied. Exposure to maximum rating conditions for extended periods may
affect device reliability.
Table 5. Absolute maximum ratings
Symbol
Ratings
Maximum value Unit
Vdd Supply voltage
-0.3 to 6
V
Vin
t(s) P
c TSTG
Input voltage on any control pin
Overpressure
Storage temperature range
-0.3 to Vdd +0.3
V
20
bar
-40 to +125
°C
rodu This is a mechanical shock sensitive device, improper handling can cause permanent
P damage to the part
te This is an ESD sensitive device, improper handling can cause permanent damage to
Obsolete Product(s) - Obsole the part
Doc ID 18171 Rev 1
9/30