English
Language : 

STM32F302X6 Datasheet, PDF (67/138 Pages) STMicroelectronics – Reset and power management
STM32F302x6 STM32F302x8
Electrical characteristics
Table 33. Typical current consumption in Run mode, code with data processing running from
Flash
Typ
Symbol
Parameter
Conditions
fHCLK
Peripherals
enabled
Peripherals
Unit
disabled
72 MHz
44.8
24.9
64 MHz
40.0
22.4
48 MHz
30.3
17.1
32 MHz
20.7
11.9
Supply current in
IDD
Run mode from
VDD supply
24 MHz
15.8
16 MHz
10.9
8 MHz
5.7
4 MHz
3.43
9.2
6.5
mA
3.55
3.22
2 MHz
2.18
1.53
1 MHz
1.56
1.19
Running from HSE
crystal clock 8 MHz,
code executing from
Flash
500 kHz
125 kHz
72 MHz
64 MHz
1.25
0.96
0.96
0.84
237.1
208.3
48 MHz
154.3
32 MHz
105.0
IDDA(1) (2)
Supply current in
Run mode from
VDDA supply
24 MHz
81.3
16 MHz
8 MHz
57.8
1.15
µA
4 MHz
1.15
2 MHz
1.15
1 MHz
1.15
500 kHz
1.15
125 kHz
1.15
1. VDDA supervisor is OFF.
2. When peripherals are enabled, the power consumption of the analog part of peripherals such as ADC, DAC, Comparators,
OpAmp etc. is not included. Refer to the tables of characteristics in the subsequent sections.
DocID025147 Rev 6
67/138
117