English
Language : 

STDS75 Datasheet, PDF (29/37 Pages) STMicroelectronics – Digital temperature sensor and thermal watchdog
STDS75
6
DC and AC parameters
DC and AC parameters
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics Tables that
follow, are derived from tests performed under the Measurement Conditions summarized in
Table 12. Operating and AC Measurement Conditions. Designers should check that the
operating conditions in their circuit match the operating conditions when relying on the
quoted parameters.
Table 12. Operating and AC measurement conditions
Parameter
STDS75
Unit
VDD/VBAT supply voltage
Ambient operating temperature (TA)
Input rise and fall times
Input pulse voltages
Input and output timing reference voltages
2.7 to 5.5
V
–55 to 125
°C
≤5
ns
0.2 to 0.8VCC
V
0.3 to 0.7VCC
V
29/37