|
STDS75 Datasheet, PDF (11/37 Pages) STMicroelectronics – Digital temperature sensor and thermal watchdog | |||
|
◁ |
STDS75
Operation
2.1
Applications information
STDS75 digital Temperature Sensors are optimal for thermal management and thermal
protection applications. They require no external components for operations except for pull-
up resistors on SCL, SDA, and OS/INT outputs. A 0.1µF bypass capacitor is recommended.
The sensing device of STDS75 is the chip itself. The typical interface connection for this
type of digital sensor is shown in Figure 4 on page 11.
Intended Applications include:
â System Thermal Management
â Computers/Disk Drivers
â Electronics/Test Equipment
â Power Supply Modules
â Consumer Products
â Battery Management
â FAX/Printers Management
â Automotive
Figure 4.
Typical 2-wire interface connection diagram
Pull-up
VDD
VDD
Pull-up
VDD
10kΩ
VDD
STDS75
0.1μF
10kΩ
10kΩ
O.S./INT(1) SCL
A0
SDA(1)
A1
A2
GND
Master
Device
I2C Address = 1001000 (1001A2A1A0)
1. SDA and OS/INT are open drain.
AI11832
11/37
|
▷ |