Table 5.29 Register 17 - Mode Control/Status (continued)
ADDRESS
NAME
DESCRIPTION
MODE DEFAULT
17.6
ALTINT
Alternate Interrupt Mode.
RW
0
0 = Primary interrupt system enabled (Default).
1 = Alternate interrupt system enabled.
See Section 5.2, "Interrupt Management," on page 47.
17.5:4
Reserved
Write as 0, ignore on read.
RW
00
17.3
PHYADBP
1 = PHY disregards PHY address in SMI access
RW
0
write.
17.2
Force
0 = normal operation;
Good Link Status 1 = force 100TX- link active;
RW
0
Note: This bit should be set only during lab testing
17.1
ENERGYON
ENERGYON – indicates whether energy is detected
RO
X
on the line (see Section 5.3.5.2, "Energy Detect
Power-Down," on page 50); it goes to “0” if no valid
energy is detected within 256ms. Reset to “1” by
hardware reset, unaffected by SW reset.
17.0
Reserved
Write as 0. Ignore on read.
RW
0
ADDRESS
18.15
18.14
18.13:8
18.7:5
18.4:0
ADDRESS
26.15:0
NAME
Reserved
MIIMODE
Table 5.30 Register 18 - Special Modes
DESCRIPTION
Write as 0, ignore on read.
MII Mode: set the mode of the digital interface, as
described in Section 5.3.9.3:
0 – MII interface.
1 – RMII interface
MODE DEFAULT
RW
0
RW,
X
NASR
Reserved
MODE
PHYAD
Write as 0, ignore on read.
Transceiver Mode of operation. Refer to Section
5.3.9.2, "Mode Bus – MODE[2:0]," on page 53 for
more details.
PHY Address.
The PHY Address is used for the SMI address and for
the initialization of the Cipher (Scrambler) key. Refer
to Section 5.3.9.1, "Physical Address Bus -
PHYAD[2:0]," on page 52 for more details.
RW,
NASR
RW,
NASR
RW,
NASR
000000
XXX
PHYAD
Table 5.31 Register 26 - Symbol Error Counter
NAME
Sym_Err_Cnt
DESCRIPTION
MODE DEFAULT
100Base-TX receiver-based error register that
RO
0
increments when an invalid code symbol is received
including IDLE symbols. The counter is incremented
only once per packet, even when the received packet
contains more than one symbol error. The 16-bit
register counts up to 65,536 (216) and rolls over to 0
if incremented beyond that value. This register is
cleared on reset, but is not cleared by reading the
register. It does not increment in 10Base-T mode.
Revision 1.0 (04-15-09)
44
DATASHEET
SMSC LAN8710/LAN8710i