EMC2300_11 Datasheet, PDF (24/82 Pages) SMSC Corporation – Fan Control Device with High Frequency PWM and Temperature Monitors | |||
|
◁ |
Fan Control Device with High Frequency PWM and Temperature Monitors
Datasheet
INT_STS1 Reg
Vccp_Error
Vccp_Error (INT1[1])
Vccp_Error_En (IER1[3])
+
VCC_Error
VCC_Error (INT1[2])
VCC_Error_En (IER1[7])
Diode 1 Limit
Diode 1_En (IER3[2])
Diode 1 Limit (INT1[4])
Ambient Limit
Ambient_En (IER3[1])
Ambient Limit (INT1[5])
+
Diode 2 Limit
Diode 2_En (IER3[3])
Diode 2 Limit (INT1[6])
INT2 (INT1[7])
+
INT#
INT_STS2 Reg
TACH1 Out-of-Limit
TACH1_En (IER2[1])
TACH1 (INT2[2])
TACH2 Out-of-Limit
TACH2 _En (IER2[2])
TACH2 (INT2[3])
TACH3 Out-of-Limit
TACH3 _En (IER2[3])
TACH4 Out-of-Limit
TACH4 _En (IER2[4])
+
TACH3 (INT2[4])
TACH4 (INT2[5])
Diode 1 Fault
Diode 1_En (IER3[2])
Diode 1 Fault (INT2[6])
Diode 2 Fault
Diode 2_En (IER3[3])
Diode 2 Fault (INT2[7])
6.4.1
Figure 6.1 Interrupt Control
Note: The diode fault bits are not mapped directly to the INT# pin. A diode fault condition forces the
diode reading register to a value of 80h, which will generate a Diode Error condition. See
section Diode Fault on page 24.
Diode Fault
The EMC2300 Chip automatically sets the associated diode fault bit to 1 when any of the following
conditions occur on the Remote Diode pins:
 The positive and negative terminal are an open circuit.
 Positive terminal is connected to VCC
 Positive terminal is connected to ground
 Negative terminal is connected to VCC
 Negative terminal is connected to ground
Revision 0.32 (06-23-08)
24
DATASHEET
SMSC EMC2300
|
▷ |