English
Language : 

AAT2601B Datasheet, PDF (7/39 Pages) Skyworks Solutions Inc. – Total Power Solution for Portable Applications
DATA SHEET
AAT2601B
Total Power Solution for Portable Applications
Electrical Characteristics1
VIN = 5V, VBAT = 3.6V, -40C ≤ TA ≤ +85C, unless noted otherwise. Typical values are TA = 25C.
Symbol
Description
Logic Control / Protection (continued)
VOCP
Over Current Protection Threshold
TC
Constant Current Mode Time Out
TK
Trickle Charge Time Out
TV
Constant Voltage Mode Time Out
ITS
Current Source from TS Pin
TS1
TS Hot Temperature Fault
TS2
TS Cold Temperature Fault
TLOOP_IN
Thermal Loop Entering Threshold
TLOOP_OUT
Thermal Loop Exiting Threshold
TREG
Thermal Loop Regulation
Load Switches / SYSOUT LDO
RDS(ON),BAT-SYSOUT
On-Resistance of BAT-SYSOUT
Load Switch
RDS(ON),CHGIN-SYSOUT
On-Resistance of CHGIN-SYSOUT
Load Switch
Sysout LDO Input Voltage Range
Sysout LDO Output Voltage
Step-Down Buck Converter
VOUTBUCK
ILIMOUTBUCK
RDS(ON)L
RDS(ON)H
FOSC
Output Voltage Accuracy
P-Channel Current Limit
High Side Switch On-Resistance
Low Side Switch On-Resistance
Oscillator Frequency
TS
Start-Up Time
LDO1 (3.3V)
VOUT1
IOUT1
ILIM1
VDO1
VOUT1(VOUT1VIN1)
VOUT1
PSRR
Output Voltage Accuracy
Output Current
Output Current Limit
Dropout Voltage
Line Regulation
Load Regulation
Power Supply Rejection Ratio
TS
Start Up Time
Conditions
CCT = 100nF, VCHGIN = 5V
Falling Threshold
Hysteresis
Rising Threshold
Hysteresis
VBAT = 3.6V
VCHGIN = 4.5V
ISYSOUT  900mA, VCHGIN = 4.5V ~ 6.0V
IOUTBUCK = 0 ~ 300mA; VIN = 2.7V ~ 5.5V
TA = 25°C
From Enable to Regulation; COUTBUCK =
4.7μF, CNOISE = On
AVIN = 3.7V to 4.2V, IOUT1 = 1mA ~ 300mA
IOUT1 = 300mA
IOUT1 = 100mA
IOUT1 = 0.5mA ~ 150mA
IOUT1 = 10mA, COUT1=22μF, 100Hz ~ 10KHz
From Enable to Regulation; C OUT1 = 22μF,
CNOISE = On
Min
71
318
2.30
4.5
3.4
1.71
-3
300
Typ
105
3
TC/8
3
75
331
25
2.39
25
115
85
100
100
0.5
3.9
1.80
0.8
0.8
0.8
1.5
100
1000
160
0.07
40
60
175
Max
79
346
2.48
150
0.75
4.2
1.89
+3
320
Units
%VCS
Hours
Hours
Hours
μA
mV
V
mV
°C
°C
°C
mΩ
Ω
V
V
V
A
Ω
Ω
MHz
μs
%
mA
mA
mV
%/V
mV
dB
μs
1. Specification over the –40°C to +85°C operating temperature range is assured by design, characterization and correlation with statistical process controls.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
202181B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • March 19, 2013
7