Next, the power dissipation for the charger can be cal-
culated by the following equation:
PD = (VCHGIN - VBAT) · ICH_CC + (VCHGIN · IOP) + (VCHGIN - VSYSOUT) · ISYSOUT
+ (VSYSOUT - VOUT1) · IOUT1 + (VSYSOUT - VOUT2) · IOUT2
+ (VSYSOUT - VOUT3) · IOUT3 + (VSYSOUT - VOUT4) · IOUT4
+ (VSYSOUT - VOUT5) · IOUT5
+
⎛
I2
OUTBUCK
·
⎝RDS(ON)L
·
VOUTBUCK
VSYSOUT
+
RDS(ON)H
· [VSYSOUT -
VSYSOUT
VOUTBUCK]⎞
⎠
Where:
PD = Total Power Dissipation by the Device
VCHGIN = CHGIN Input Voltage
VBAT = Battery Voltage at the BAT Pin
ICH_CC = Constant Charge Current Programmed for the
Application
IOP = Quiescent Current Consumed by the IC for Normal
Operation [0.5mA]
VSYSOUT and ISYSOUT = Output voltage and load current
from the SYSOUT pin for the system LDOs and step-
down converter [3.9V out for SYSOUT]
RDS(ON)H and RDS(ON)L = On-resistance of step-down high
and low side MOSFETs [0.8 each]
VOUTX and IOUTX = Output voltage and load currents for
the LDOs and step-down converter [3V out for each
LDO]
By substitution, we can derive the maximum charge cur-
rent before reaching the thermal limit condition (TREG =
100°C, Thermal Loop Regulation). The maximum charge
current is the key factor when designing battery charger
applications.
⎛(TREG - TA)
⎝
I = CH_CC(MAX)
θJA
- (VCHGIN · IOP)⎞⎠ - (VCHGIN - VSYSOUT) · ISYSOUT)
- [(VSYSOUT - VOUT1) · IOUT1] - (VSYSOUT - VOUT2) · IOUT2
- [(VSYSOUT - VOUT3) · IOUT3] - (VSYSOUT - VOUT4) · IOUT4
- (VSYSOUT - VOUT5) · IOUT5
-
I2
OUTBUCK
·
⎛⎝RDS(ON)L
·
VOUTBUCK
VSYSOUT
+
RDS(ON)H · (VSYSOUT - VOUTBUCK)⎞
VSYSOUT
⎠
VCHGIN - VBAT
In general, the worst condition is when there is the
greatest voltage drop across the charger, when battery
voltage is charged up to just past the preconditioning
voltage threshold and the LDOs and step-down con-
verter are sourcing full output current.
Thermal Overload Protection
The AAT2601B integrates thermal overload protection
circuitry to prevent damage resulting from excessive
thermal stress that may be encountered under fault con-
ditions, for example. This circuitry disables all regulators
if the AAT2601B die temperature exceeds 140°C, and
prevents the regulators from being enable until the die
temperature drops by 15°C (typ).
Synchronous Step-Down
Converter (Buck)
The AAT2601B contains a high performance 300mA,
1.5MHz synchronous step-down converter. The step-
down converter operates to ensure high efficiency per-
formance over all load conditions. It requires only three
external power components (CIN, COUT, and L). A high DC
gain error amplifier with internal compensation controls
the output. It provides excellent transient response and
load/line regulation. Transient response time is typically
less than 20μs. The converter has soft start control to
limit inrush current and transitions to 100% duty cycle
at drop out.
The step-down converter input pin PVIN should be con-
nected to the SYSOUT LDO output pin. The output volt-
age is internally fixed at 1.8V. Power devices are sized
for 300mA current capability while maintaining over
90% efficiency at full load.
Input/Output Capacitor and Inductor
Apart from the input capacitor that is shared with the LDO
inputs, only a small L-C filter is required at the output side
for the step-down converter to operate properly. Typically,
a 3.3μH inductor such as the Sumida CDRH2D11NP-
3R3NC and a 4.7μF ceramic output capacitor are recom-
mended for low output voltage ripple and small compo-
nent size. Ceramic capacitors with X5R or X7R dielectrics
are highly recommended because of their low ESR and
small temperature coefficients. A 10μF ceramic input
capacitor is sufficient for most applications.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com