SKY66109_11 Datasheet, PDF (3/14 Pages) Skyworks Solutions Inc. – Integrated PA with up to plus 22.5 dBm output power
DATA SHEET • SKY66109-11: ZIGBEE/SMART ENERGY FEM
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY66109-11 are provided
in Table 2. The recommended operating conditions are specified
in Table 3 and electrical specifications are provided in Tables 4
and 5.
The state of the SKY66109-11 is determined by the logic provided
in Tables 6 and 7.
Table 2. SKY66109-11 Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Minimum
Maximum
Units
Supply voltage
VCC1
–0.3
+3.6
V
Supply voltage
VCC2
–0.3
+3.8 (Note 2)
V
Control pin voltages
–0.3
+3.6
V
Transmit output power at ANT1 or ANT2 port into 50 Ω load
POUT_TX_MAX
+22.5
dBm
Transmit input power at the TXN and TXP ports
PIN_TX_MAX
+6
dBm
Receive input power at ANT1 or ANT2 ports, LNA mode
PIN_RX_MAX
+10
dBm
Receive input power at ANT1 or ANT2 ports, bypass mode
PIN_RX_BYPASS_MAX
+15
dBm
Operating temperature
TA
–40
+125
C
Storage temperature
TSTG
–40
+125
C
Electrostatic discharge:
ESD
Human Body Model (HBM), Class 1C
1000
V
Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other
parameters set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
Note 2: Vcc2 is restricted to +3.6 V when operated at TA = 125 C.
CAUTION: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device. This device
must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body
or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times.
Table 3. Recommended Operating Conditions
Parameter
Symbol
Minimum
Typical
Maximum
Units
Supply voltage for balun bias
VB_IN, VB_OUT
1.6
3.6
V
Supply voltage on VCC pins
VCC1, VCC2
2.0
3.0
3.6
V
Operating temperature
TA
–40
+25
+125
C
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
203034F • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • August 13, 2015
3