Table 5. 2-Wire Control Interface Characteristics1,2,3
(VDD = 2.7 to 5.5 V, VIO = 1.5 to 3.6 V, TA = –20 to 85 °C)
Parameter
Symbol Test Condition
Min
Typ
Max
Unit
SCLK Frequency
SCLK Low Time
SCLK High Time
SCLK Input to SDIO Setup
(START)
SCLK Input to SDIO Hold (START)
SDIO Input to SCLK Setup
SDIO Input to SCLK Hold4,5
SCLK input to SDIO Setup (STOP)
STOP to START Time
SDIO Output Fall Time
fSCL
tLOW
tHIGH
tSU:STA
tHD:STA
tSU:DAT
tHD:DAT
tSU:STO
tBUF
tf:OUT
0
—
1.3
—
0.6
—
0.6
—
0.6
—
100
—
0
—
0.6
—
1.3
—
—
20
+
0.1
---C----b----
1 pF
400
kHz
—
µs
—
µs
—
µs
—
µs
—
ns
900
ns
—
µs
—
µs
250
ns
SDIO Input, SCLK Rise/Fall Time
tf:IN
tr:IN
—
20
+
0.1
---C----b----
1 pF
300
ns
SCLK, SDIO Capacitive Loading
Cb
—
—
50
pF
Input Filter Pulse Suppression
tSP
—
—
50
ns
Notes:
1. When VIO = 0 V, SCLK and SDIO are low-impedance. 2-wire control interface is I2C compatible.
2. When selecting 2-wire mode, the user must ensure that a 2-wire start condition (falling edge of SDIO while SCLK is
high) does not occur within 300 ns before the rising edge of RST.
3. When selecting 2-wire mode, the user must ensure that SCLK is high during the rising edge of RST, and stays high
until after the first start condition.
4. The Si4720/21 delays SDIO by a minimum of 300 ns from the VIH threshold of SCLK to comply with the minimum
tHD:DAT specification.
5. The maximum tHD:DAT has only to be met when fSCL = 400 kHz. At frequencies below 400 KHz, tHD:DAT may be
violated as long as all other timing parameters are met.
8