4.16 I2C
EZR32LG330 Data Sheet
Electrical Specifications
Table 4.21. I2C Standard-Mode (Sm)
Parameter
Symbol
Min
Typ
Max
Unit
SCL clock frequency
fSCL
0
─
100 1
kHz
SCL clock low time
tLOW
4.7
─
─
µs
SCL clock high time
tHIGH
4.0
─
─
µs
SDA set-up time
tSU,DAT
250
─
─
ns
SDA hold time
tHD,DAT
8
─
34502, 3
ns
Repeated START condition set-up time
tSU,STA
4.7
─
─
µs
(Repeated) START condition hold time
tHD,STA
4.0
─
─
µs
STOP condition set-up time
tSU,STO
4.0
─
─
µs
Bus free time between a STOP and a START
tBUF
4.7
─
─
µs
condition
Note:
1. For the minimum HFPERCLK frequency required in Standard-mode, see the I2C chapter in the EZR32LG Reference Manual.
2. The maximum SDA hold time (tHD,DAT) needs to be met only when the device does not stretch the low time of SCL (tLOW).
3. When transmitting data, this number is guaranteed only when I2Cn_CLKDIV < ((3450 * 10-9 [s] * fHFPERCLK [Hz]) - 4).
Table 4.22. I2C Fast-Mode (Fm)
Parameter
Symbol
Min
Typ
Max
Unit
SCL clock frequency
fSCL
0
─
4001
kHz
SCL clock low time
tLOW
1.3
─
─
µs
SCL clock high time
tHIGH
0.6
─
─
µs
SDA set-up time
tSU,DAT
100
─
─
ns
SDA hold time
tHD,DAT
8
─
9002 , 3
ns
Repeated START condition set-up time
tSU,STA
0.6
─
─
µs
(Repeated) START condition hold time
tHD,STA
0.6
─
─
µs
STOP condition set-up time
tSU,STO
0.6
─
─
µs
Bus free time between a STOP and a START condi-
tBUF
1.3
─
tion
─
µs
Note:
1. For the minimum HFPERCLK frequency required in Fast-mode, see the I2C chapter in the EZR32LG Reference Manual.
2. The maximum SDA hold time (tHD,DAT) needs to be met only when the device does not stretch the low time of SCL (tLOW).
3. When transmitting data, this number is guaranteed only when I2Cn_CLKDIV < ((900 * 10-9 [s] * fHFPERCLK [Hz]) - 4).
silabs.com | Smart. Connected. Energy-friendly.
Rev. 1.1 | 54