Si7015-A20
Table 2. General Specifications (Continued)
1.9 < VDD < 3.6 V; TA = –40 to 85 °C (G grade) or 0 to 70 °C (F grade); default conversion time unless otherwise noted.
Parameter
Symbol
Test Condition1
Min
Typ
Max Unit
Wake Up Time
tCS From CS < VIL to ready for a temp/RH
—
—
1
ms
conversion
Power Up Time
tPU From VDD ≥ 1.9 V to ready for a temp/
—
RH conversion, 25°C
From VDD ≥ 1.9 V to ready for a temp/
—
RH conversion, full temperature range
18
25
ms
—
80
ms
Notes:
1. Initiating a RH measurement will also automatically initiate a temperature measurement. The total conversion time will
be tCONV(RH) + tCONV(T).
2. No conversion or I2C transaction in progress. Typical values measured at 25 °C.
3. Occurs once during powerup. Duration is <5 msec.
4. Occurs during I2C commands for Read Device ID and Read Firmware Version. Duration is < 100 µs when I2C clock
speed is >100 kHz.
Table 3. I2C Interface Specifications1
1.9 VDD  3.6 V; TA = 0 to 70 °C (F grade) or –40 to +85 °C (G grade) unless otherwise noted.
Parameter
Symbol
Test Condition
Min
Typ
Hysteresis
VHYS High-to-low versus low-to- 0.05 x VDD —
high transition
SCLK Frequency
fSCL
—
—
SCL High Time
tSKH
0.6
—
SCL Low Time
tSKL
1.3
—
Start Hold Time
tSTH
0.6
—
Start Setup Time
tSTS
0.6
—
Stop Setup Time
tSPS
0.6
—
Bus Free Time
tBUF
Between Stop and Start
1.3
—
SDA Setup Time
tDS
100
—
SDA Hold Time
tDH
100
—
SDA Valid Time
tVD;DAT From SCL low to data valid
—
—
SDA Acknowledge Valid Time tVD;ACK From SCL low to data valid
—
—
Suppressed Pulse Width2
tSP
50
—
Notes:
1. All values are referenced to VIL and/or VIH.
2. Pulses up to and including 50ns will be suppressed.
Max Unit
—
V
400 kHz
—
µs
—
µs
—
µs
—
µs
—
µs
—
µs
—
ns
—
ns
0.9
µs
0.9
µs
—
ns
Rev. 1.0