SI7015-A20 Datasheet, PDF (5/39 Pages) Silicon Laboratories – DIGITAL IC HUMIDITY AND TEMPERATURE SENSOR | |||
|
◁ |
Si7015-A20
Table 2. General Specifications (Continued)
1.9 < VDD < 3.6 V; TA = â40 to 85 °C (G grade) or 0 to 70 °C (F grade); default conversion time unless otherwise noted.
Parameter
Symbol
Test Condition1
Min
Typ
Max Unit
Wake Up Time
tCS From CS < VIL to ready for a temp/RH
â
â
1
ms
conversion
Power Up Time
tPU From VDD ⥠1.9 V to ready for a temp/
â
RH conversion, 25°C
From VDD ⥠1.9 V to ready for a temp/
â
RH conversion, full temperature range
18
25
ms
â
80
ms
Notes:
1. Initiating a RH measurement will also automatically initiate a temperature measurement. The total conversion time will
be tCONV(RH) + tCONV(T).
2. No conversion or I2C transaction in progress. Typical values measured at 25 °C.
3. Occurs once during powerup. Duration is <5 msec.
4. Occurs during I2C commands for Read Device ID and Read Firmware Version. Duration is < 100 µs when I2C clock
speed is >100 kHz.
Table 3. I2C Interface Specifications1
1.9ï£ VDD ï£ 3.6 V; TA = 0 to 70 °C (F grade) or â40 to +85 °C (G grade) unless otherwise noted.
Parameter
Symbol
Test Condition
Min
Typ
Hysteresis
VHYS High-to-low versus low-to- 0.05 x VDD â
high transition
SCLK Frequency
fSCL
â
â
SCL High Time
tSKH
0.6
â
SCL Low Time
tSKL
1.3
â
Start Hold Time
tSTH
0.6
â
Start Setup Time
tSTS
0.6
â
Stop Setup Time
tSPS
0.6
â
Bus Free Time
tBUF
Between Stop and Start
1.3
â
SDA Setup Time
tDS
100
â
SDA Hold Time
tDH
100
â
SDA Valid Time
tVD;DAT From SCL low to data valid
â
â
SDA Acknowledge Valid Time tVD;ACK From SCL low to data valid
â
â
Suppressed Pulse Width2
tSP
50
â
Notes:
1. All values are referenced to VIL and/or VIH.
2. Pulses up to and including 50ns will be suppressed.
Max Unit
â
V
400 kHz
â
µs
â
µs
â
µs
â
µs
â
µs
â
µs
â
ns
â
ns
0.9
µs
0.9
µs
â
ns
Rev. 1.0
5
|
▷ |