SI7015-A20 Datasheet, PDF (4/39 Pages) Silicon Laboratories – DIGITAL IC HUMIDITY AND TEMPERATURE SENSOR | |||
|
◁ |
Si7015-A20
1. Electrical Specifications
Unless otherwise specified, all min/max specifications apply over the recommended operating conditions.
Table 1. Recommended Operating Conditions
Parameter
Symbol Test Condition
Min
Typ
Max
Unit
Power Supply
VDD
1.9
â
3.6
V
Operating Temperature
TA
F grade
0
â
+70
°C
Operating Temperature
TA
G grade
â40
â
+85
°C
Table 2. General Specifications
1.9 < VDD < 3.6 V; TA = â40 to 85 °C (G grade) or 0 to 70 °C (F grade); default conversion time unless otherwise noted.
Parameter
Symbol
Test Condition1
Min
Typ
Max Unit
Input Voltage High
VIH
AD0, SCL, SDA pins
0.7xVDD
â
â
V
Input Voltage Low
VIL
AD0, SCL, SDA pins
â
â
0.3xVDD V
Input Voltage Range VIN SCL, SDA, RSTb pins with respect to
0.0
GND
â
VDD
V
Input Leakage
IIL
SCL, SDA pins; VIN = GND
CS pin (200K nominal pull up);
Vin = GND
â
â
5xVDD
1
μA
μA
Output Voltage Low VOL SDA pin; IOL = 2.5 mA; VDD = 3.3 V
â
SDA pin; IOL = 1.2 mA;
â
VDD = 1.9 V
Current
Consumption
IDD
RH conversion in progress
â
Temperature conversion in progress
â
â
0.6
V
â
0.4
V
150
180
µA
90
120
µA
CS < VIL; no conversion in progress;
â
VDD = 3.3 V;
SDA = SCL ⥠VIH; HEAT = 1
Standby2, â40 to +85°C
â
Peak IDD during powerup3
â
Peak IDD during I2C operations4
â
Conversion Time
tCONV
RH Normal (Fast = 0)
â
RH Fast (Fast = 1)
â
24
â
mA
0.06
0.62 µA
3.5
4.0
mA
3.5
4.0
mA
5.8
7.0
ms
2.6
3.1
ms
Temperature Normal (Fast = 0)
â
4.0
6.2
ms
Temperature Fast (Fast = 1)
â
1.5
2.4
ms
Notes:
1. Initiating a RH measurement will also automatically initiate a temperature measurement. The total conversion time will
be tCONV(RH) + tCONV(T).
2. No conversion or I2C transaction in progress. Typical values measured at 25 °C.
3. Occurs once during powerup. Duration is <5 msec.
4. Occurs during I2C commands for Read Device ID and Read Firmware Version. Duration is < 100 µs when I2C clock
speed is >100 kHz.
4
Rev. 1.0
|
▷ |