English
Language : 

SI8285 Datasheet, PDF (23/32 Pages) Silicon Laboratories – System Safety Features
Si8285/86 Data Sheet
Electrical Specifications
Table 4.5. IEC 60664-1 Ratings
Parameter
Test Condition
Basic Isolation Group
Installation Classification
Material Group
Rated Mains Voltages ≤ 150 VRMS
Rated Mains Voltages ≤ 300 VRMS
Rated Mains Voltages ≤ 600 VRMS
Table 4.6. VDE0884-10 Insulation Characteristics1
Specification
WB SOIC-16
I
I-IV
I-IV
I-IV
Parameter
Symbol
Test Condition
Characteristic
Unit
WB SOIC-16
Maximum Working Insulation Voltage
VIORM
1414
V peak
Input to Output Test Voltage
VPR
Method b1 (VIORM x 1.875 = VPR, 100%
Production Test, tm = 1 sec, Partial Dis-
charge < 5 pC)
2652
V peak
Transient Overvoltage
VIOTM
t = 60 sec
8000
V peak
Surge Voltage
VIOSM
Tested per IEC 60065 with surge voltage
of 1.2 µs/50 µs with magnitude 6250 V x
1.6 = 10 kV
6250
kV peak
Pollution Degree (DIN VDE 0110)
2
Insulation Resistance at TS, VIO = 500 V
RS
>109
Ω
Note:
1. This isolator is suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensur-
ed by protective circuits. The Si828x provides a climate classification of 40/125/21.
Table 4.7. IEC Safety Limiting Values1, 2
Parameter
Symbol
Test Condition
Max
Unit
WB SOIC-16
Case Temperature
TS
150
°C
Input Current
IS
θJA = 60 °C/W
30
mA
VDDA = 5.5 V, VDDB–VSSB = 30 V
TJ = 150 °C, TA = 25 °C
Device Power Dis-
PD
sipation
0.9
W
Note:
1. Maximum value allowed in the event of a failure.
2. The Si828x is tested with RH = RL = 0 Ω, CL = 5 nF, and a 200 kHz, 50% duty cycle square wave input.
silabs.com | Smart. Connected. Energy-friendly.
Preliminary Rev. 0.6 | 22