English
Language : 

SI846X Datasheet, PDF (16/36 Pages) Silicon Laboratories – LOW POWER SIX-CHANNEL DIGITAL ISOLATOR
Si8460/61/62/63
Table 5. Electrical Characteristics1 (Continued)
(VDD1 = 2.70 V, VDD2 = 2.70 V, TA = –40 to 125 °C; applies to narrow-body SOIC package)
Parameter
All Models
Output Rise Time
Symbol Test Condition
Min
tr
CL = 15 pF
—
See Figure 1
Typ
Max Unit
4.8
6.5
ns
Output Fall Time
tf
CL = 15 pF
—
3.2
4.6
ns
See Figure 1
Common Mode Transient
Immunity
CMTI
VI = VDD or 0 V
—
25
— kV/µs
Start-up Time4
tSU
—
15
40
µs
d Notes:
1. Specifications in this table are also valid at VDD1 = 2.6 V and VDD2 = 2.6 V when the operating temperature range is
e constrained to TA = 0 to 85 °C.
2. The nominal output impedance of an isolator driver channel is approximately 85 , ±40%, which is a combination of the
d value of the on-chip series termination resistor and channel resistance of the output driver FET. When driving loads
n where transmission line effects will be a factor, output pins should be appropriately terminated with controlled
s impedance PCB traces.
e n 3. tPSK(P-P) is the magnitude of the difference in propagation delay times measured between different units operating at the
same supply voltages, load, and ambient temperature.
m ig 4. Start-up time is the time period from the application of power to valid data at the output.
m s Table 6. Regulatory Information*
o e CSA
c D The Si84xx is certified under CSA Component Acceptance Notice 5A. For more details, see File 232873.
61010-1: Up to 300 VRMS reinforced insulation working voltage; up to 600 VRMS basic insulation working voltage.
e 60950-1: Up to 130 VRMS reinforced insulation working voltage; up to 600 VRMS basic insulation working voltage.
R w VDE
t e The Si84xx is certified according to IEC 60747-5-2. For more details, see File 5006301-4880-0001.
o N 60747-5-2: Up to 560 Vpeak for basic insulation working voltage.
UL
N r The Si84xx is certified under UL1577 component recognition program. For more details, see File E257455.
fo Rated up to 2500 VRMS isolation voltage for basic insulation.
*Note: Regulatory Certifications apply to 2.5 kVRMS rated devices which are production tested to 3.0 kVRMS for 1 sec.
For more information, see "5. Ordering Guide" on page 29.
16