S-8249AAP-M6T1U Datasheet, PDF (8/22 Pages) Seiko Instruments Inc – VOLTAGE MONITORING IC WITH CELL BALANCING FUNCTION | |||
|
◁ |
VOLTAGE MONITORING IC WITH CELL BALANCING FUNCTION
S-8249 Series
Rev.1.2_00
Table 8 (2 / 2)
(Ta = +25°C unless otherwise specified)
Item
Symbol
Condition
Min.
Typ.
Max. Unit
Delay time
Cell balancing detection
delay time
tBU
â
tBU Ã 0.8 tBU tBU Ã 1.2 ms
Cell balancing release
delay time
tBL
â
tBL Ã 0.8 tBL tBL Ã 1.2 ms
Overcharge detection delay
time
tCU
â
tCU Ã 0.8 tCU tCU Ã 1.2 ms
Overcharge release delay
time
tCL
â
tCL Ã 0.8 tCL tCL Ã 1.2 ms
Output current
CB pin output current
CB pin sink current
ICBS
V1 = VBU + 0.1 V, SW2 = ON,
V4 = 0.5 V
30
â
â
mA
CB pin leakage current
ICBL
V1 = VBL â 0.1 V, SW2 = ON,
V4 = 6.0 V
â
â
0.1
μA
CO pin output current (output form: CMOS output, output logic: active "H")
CO pin sink current
ICOL
V1 = VCL â 0.1 V, SW4 = ON,
V5 = 0.5 V
5.0
â
â
mA
CO pin source current
ICOH
V1 = VCU + 0.1 V, SW4 = ON,
V5 = V1 â 0.5 V
1.0
â
â
mA
CO pin output current (output form: CMOS output, output logic: active "L")
CO pin sink current
ICOL
V1 = VCU + 0.1 V, SW4 = ON,
V5 = 0.5 V
5.0
â
â
mA
CO pin source current
ICOH
V1 = VCL â 0.1 V, SW4 = ON,
V5 = V1 â 0.5 V
1.0
â
â
mA
CO pin output current (output form: Nch open-drain output, output logic: active "H")
CO pin sink current
ICOL
V1 = VCL â 0.1 V, SW4 = ON,
V5 = 0.5 V
5.0
â
â
mA
CO pin leakage current
ICOHL
V1 = VCU + 0.1 V, SW4 = ON,
V5 = 6.0 V
â
â
0.1
μA
CO pin output current (output form: Nch open-drain output, output logic: active "L")
CO pin sink current
ICOL
V1 = VCU + 0.1 V, SW4 = ON,
V5 = 0.5 V
5.0
â
â
mA
CO pin leakage current
ICOHL
V1 = VCL â 0.1 V, SW4 = ON,
V5 = 6.0 V
â
â
0.1
μA
8
|
▷ |