English
Language : 

S-8232 Datasheet, PDF (4/27 Pages) Seiko Instruments Inc – BATTERY PROTECTION IC FOR 2-SERIAL-CELL PACK
BATTERY PROTECTION IC FOR 2-SERIAL-CELL PACK
S-8232 Series
Rev.5.4_00
Table 1 (2 / 2)
Product name / Item
Overcharge
detection
voltage 1, 2
VCU
Overcharge
release voltage 1, 2
VCD
Overdischarge
detection
voltage 1, 2
VDD
S-8232NAFT-T2-G 4.325 V ± 25 mV 4.325 V ± 25 mV *1 *3 2.40 V ± 80 mV
Overdischarge
release
voltage1, 2
VDU
3.00 V ± 100 mV
Overcurrent
detection
voltage 1
VIOV1
Overcharge
detection 0 V battery
delay time charging
tCU
function
(C3 = 0.22 µF)
0.15 V ± 20 mV
1.0 s Unavailable
S-8232NBFT-T2-G 4.35 V ± 25 mV 4.25 V ± 50 mV 3.00 V ± 80 mV 3.70 V ± 100 mV 0.30 V ± 20 mV
1.0 s Unavailable
S-8232NCFT-T2-G 4.275 V ± 25 mV 4.05 V ± 50 mV 2.20 V ± 80 mV 3.00 V ± 100 mV 0.20 V ± 20 mV
1.0 s Unavailable
S-8232NDFT-T2-G 4.35 V ± 25 mV 4.15 V ± 50 mV 2.30 V ± 80 mV 2.30 V ± 80 mV 0.15 V ± 20 mV 1.0 s
Available
S-8232NEFT-T2-G 4.35 V ± 25 mV 4.15 V ± 50 mV 2.30 V ± 80 mV 3.00 V ± 100 mV 0.23 V ± 20 mV
S-8232NFFT-T2-G 4.325 V ± 25 mV 4.1 V ± 50 mV *3 2.30 V ± 80 mV 2.90 V ± 100 mV 0.21 V ± 20 mV
1.0 s
Available
1.0 s Unavailable
S-8232NGFT-T2-G 4.35 V ± 25 mV 4.15 V ± 50 mV 2.60 V ± 80 mV 3.00 V ± 100 mV 0.30 V ± 20 mV 1.0 s
Available
S-8232NHFT-T2-G 4.28 V ± 25 mV 4.05 V ± 50 mV 2.30 V ± 80 mV 2.90 V ± 100 mV 0.11 V ± 20 mV
S-8232NIFT-T2-G 4.25 V ± 25 mV 4.05 V ± 50 mV *3 2.50 V ± 80 mV 3.00 V ± 100 mV 0.15 V ± 20 mV
1.0 s Unavailable
1.0 s Unavailable
S-8232NJFT-T2-G 4.28 V ± 25 mV 4.05 V ± 50 mV 2.30 V ± 80 mV 2.90 V ± 100 mV 0.11 V ± 20 mV 1.0 s
Available
S-8232NKFT-T2-G 4.35 V ± 25 mV 4.15 V ± 50 mV 2.30 V ± 80 mV 2.30 V ± 80 mV 0.12 V ± 20 mV 1.0 s
Available
S-8232NLFT-T2-G 4.30 V ± 25 mV 4.05 V ± 50 mV 2.30 V ± 80 mV 3.00 V ± 100 mV 0.23 V ± 20 mV 1.0 s
Available
S-8232NMFT-T2-G 4.28 V ± 25 mV
S-8232NNFT-T2-G 4.28 V ± 25 mV
S-8232NOFT-T2-G 4.295 V ± 25 mV
4.05 V ± 50 mV
4.08 V ± 50 mV *3
4.045 V ± 50 mV *3
2.30 V ± 80 mV
2.20 V ± 80 mV
2.20 V ± 80 mV
2.90 V ± 100 mV
2.40 V ± 100 mV
2.40 V ± 100 mV
0.08 V ± 20 mV
0.13 V ± 20 mV
0.13 V ± 20 mV
1.0 s
Available
1.0 s Unavailable
1.0 s Unavailable
S-8232NPFT-T2-G 4.25 V ± 25 mV 4.05 V ± 50 mV 2.30 V ± 80 mV 3.00 V ± 100 mV 0.30 V ± 20 mV
1.0 s Unavailable
S-8232NQFT-T2-G 4.25 V ± 25 mV 4.05 V ± 50 mV 2.60 V ± 80 mV 3.00 V ± 100 mV 0.30 V ± 20 mV
1.0 s Unavailable
S-8232NRFT-T2-G 4.15 V ± 25 mV 3.95 V ± 50 mV 2.60 V ± 80 mV 3.00 V ± 100 mV 0.30 V ± 20 mV
1.0 s Unavailable
S-8232NSFT-T2-G 4.15 V ± 25 mV 3.95 V ± 50 mV 2.30 V ± 80 mV 3.00 V ± 100 mV 0.30 V ± 20 mV
1.0 s Unavailable
S-8232NTFT-T2-G 4.225 V ± 25 mV 4.15 V ± 50 mV 2.00 V ± 80 mV 2.00 V ± 100 mV 0.09 V ± 20 mV
1.0 s Unavailable
S-8232NUFT-T2-G 3.85 V ± 25 mV 3.75 V ± 50 mV 2.23 V ± 80 mV 2.23 V ± 80 mV 0.15 V ± 20 mV 1.0 s
Available
S-8232NWFT-T2-G 4.210 V ± 25 mV 4.125 V ± 50 mV 2.00 V ± 80 mV 2.00 V ± 80 mV 0.09 V ± 20 mV 1.0 s Unavailable
*1. No overcharge detection / release hysteresis
*2. The magnification of final overcharge is 1.11; the others are 1.25.
*3. No final overcharging function
*4. Refer to the *2 in the “„ Operation”.
Remark 1. Please contact our sales office for the products with detection voltage value other than those
specified above.
2. The overdischarge detection voltage can be selected within the range from 1.7 to 3.0 V. When the
overdischarge detection voltage is higher than 2.6 V, the overcharge detection voltage and the
overcharge release voltage are limited as “Table 2”.
Overdischarge
detection voltage 1, 2
VDD
1.70 to 2.60 V
1.70 to 2.80 V
1.70 to 3.00 V
Table 2
Overcharge
detection voltage 1, 2
VCU
3.85 to 4.60 V
3.85 to 4.60 V
3.85 to 4.50 V
Voltage difference between overcharge detection
voltage and overcharge release voltage
VCU − VCD
0 to 0.30 V
0 to 0.20 V
0 to 0.10 V
4
Seiko Instruments Inc.