 Operation Timing Charts
1. Voltage regulator (C/G type)
VIN [V]
VSS
t [s]
VOUT [V]
VSS
*1 *1
*2
t1 t2
t [s]
VPF [V]
H
L
VSS
t [s]
*1. Indicates shutdown state. When the load current (IOUT) is less than 1 μA, the output voltage (VOUT) is
not always VSS level.
*2. When the VOUT is shorted at t1, VOUT becomes VSS level. When the short of VOUT is removed at t2,
VOUT returns to normal output.
Figure 15
2. Voltage detector (A/B/F type)
VIN or VOUT [V]
VHYS
+VDET
âVDET
t [s]
VOR [V]
tpd*1
tpd*1
tpd*1
t [s]
*1. Output delay time (tpd) of the voltage detector can be changed with an external capacitance value to
CD pin. Delay circuit is not included in C/E/G type.
Remark Pull up VOR through a resistor to VIN or VOUT.