S-87X_1 Datasheet, PDF (16/53 Pages) Seiko Instruments Inc – HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION | |||
|
◁ |
HIGH WITHSTAND-VOLTAGE VOLTAGE REGULATOR WITH RESET FUNCTION
S-87x Series
Rev.7.2_00
6. S-8730xxC Series
Table 11
Item
Symbol
Condition
Voltage Regulator
Output voltage
I/O voltage difference
Line regulation
Load regulation
Input voltage
Temperature
coefficient of VOUT
Shutdown output
voltage
Voltage Detector
Operating voltage
Temperature
characteristic of âVDET
Detection voltage
Sink current
Leakage current
Hysteresis width
VOUT
Vdif
ÎVOUT1
ÎVOUT2
VIN
ÎVOUT
ÎTa
VOUTOFF
VIN=5 V, IOUT=30 mA
IOUT=30 mA
VIN=4 to 24 V,
IOUT=30 mA
VIN=5 V,
IOUT=50 μA to 40 mA
â¯
VIN=5 V, IOUT=30 mA,
Ta=â40°C to +85°C
VIN=5V,
VPF =âLâ, RL=1 MΩ
Vopr
Î â VDET
ÎTa
âVDET
IDOUT
ILEAK
â¯
Ta=â40°C S-873069C
to +85°C S-873025C to
S-873021C
S-873069C
S-873025C
S-873024C
S-873023C
S-873022C
S-873021C
Nch,
VDS=0.5 V
VIN=1.3 V
Other than below
VIN=2.4 V
S-873069C,
S-873025C
VIN=3.6 V
S-873069C
Nch, VDS=24 V, VIN=10 V
VHYS
â¯
Input current
Current consumption
ISS
VIN=5 V, Unloaded
Input Voltage
lof
VPF =âLâ, Shutdown, VIN=5 V
Shutdown input voltage VIL
VPF =âLâ, Shutdown, VIN=5 V
VIH
VPF =âHâ, Power on, VIN=5 V
(Unless otherwise specified: Ta=25°C)
Min.
Typ.
Max.
Unit
Test
circuit
2.928 3.000 3.072 V
1
â¯
0.45 0.70
â¯
15
50 mV
â¯
15
50
â¯
â¯
24
V
â¯
±0.23
±0.92
mV
/°C
â¯
â¯
0.1 V
6
1.3
â¯
24
V
2
â¯
±0.5 ±2.0 mV
â¯
±0.3 ±1.2 /°C
6.734 6.900 7.066 V
2.440 2.500 2.560
2.342 2.400 2.458
2.244 2.300 2.356
2.147 2.200 2.253
2.049 2.100 2.151
0.25 0.60
⯠mA
4
1.50 2.60
â¯
3.00 4.50
â¯
â¯
â¯
0.1 μA
âVDET
Ã0.03
â¯
âVDET
Ã0.08
V
2
â¯
3
8
μA
5
â¯
1.5
3.5
â¯
â¯
0.4 V
6
2.0
â¯
â¯
16
Seiko Instruments Inc.
|
▷ |