English
Language : 

S-24CS16A Datasheet, PDF (25/53 Pages) Seiko Instruments Inc – 2-WIRE CMOS SERIAL E2PROM
Rev.4.3_00
2-WIRE CMOS SERIAL E2PROM
S-24CS16A
5. 2 Wait for the initialization sequence to end
The E2PROM executes initialization during the time that the supply voltage is increasing to its normal value. All
instructions must wait until after initialization. The relationship between the initialization time (tINIT) and rise time
(tRISE) is shown in Figure 30.
100 m
10 m
E2PROM
initialization time
(tINIT) Max.
[s]
1.0 m
100 µ
10 µ
1.0 µ
1.0 µ 10 µ 100 µ 1.0 m 10 m 100 m
Rise time (tRISE)
[s]
Figure 30 Initialization Time of E2PROM
Seiko Instruments Inc.
25