English
Language : 

S-34C02A Datasheet, PDF (24/34 Pages) Seiko Instruments Inc – 2-WIRE CMOS SERIAL E2PROM FOR DIMM SERIAL PRESENCE DETECT
2-WIRE CMOS SERIAL E2PROM FOR DIMM SERIAL PRESENCE DETECT
S-34C02A
Rev.1.2_00
4. Acknowledge check
The I2C-bus protocol includes an acknowledge check function as a handshake function to prevent a communication
error. This function allows detection of a communication failure during data communication between the master device
and S-34C02A. This function is effective to prevent malfunction, so it is recommended to perform an acknowledge
check with the master device.
5. Built-in power-on-clear circuit
The S-34C02A has a built-in power-on-clear circuit that initializes itself at the same time during power-on.
Unsuccessful initialization may cause a malfunction. To operate the power-on-clear circuit normally, the following
conditions must be satisfied to raise the power supply voltage.
5. 1 Raising power supply voltage
Shown in Figure 24, raise the power supply voltage from 0.2 V max., within the time defined as tRISE which is the
time required to reach the power supply voltage to be set.
For example, if the power supply voltage is 5.0 V, tRISE = 200 ms seen in Figure 25. The power supply voltage must
be raised within 200 ms.
tRISE (Max.)
Power Supply Voltage (VCC)
VINIT (Max.)
0.2 V
0 V*1
tINIT*2 (Max.)
*1. 0 V means there is no difference in potential between the VCC pin and the GND pin of the S-34C02A.
*2. tINIT is the time required to initialize the S-34C02A. No instructions are accepted during this time.
Figure 24 Raising Power Supply Voltage
24
Seiko Instruments Inc.