S-35740C01A-K8T2U Datasheet, PDF (22/31 Pages) Seiko Instruments Inc – Operation temperature range
FOR AUTOMOTIVE 125°C OPERATION 2-WIRE INTERVAL TIMER CONVENIENCE TIMER
S-35740 Series
Rev.1.1_00
2. When power supply voltage is raised at ENBL pin = "H"
Set the ENBL pin to "L" after the power supply voltage reaches 1.8 V or higher. If the ENBL pin is set to "L" for 500
ms or longer, the oscillation start signal becomes "H", and the crystal oscillation circuit normally oscillates. After that,
if the ENBL pin is set to "H", the oscillation start signal becomes "L" within 500 ms, and the oscillation status is
maintained.
The current consumption increases to 1.7 μA typ. while the ENBL pin is set to "L".
10 ms
1.8 V
(Operation power supply voltage min.)
0.2 V or lower
07*1
ENBL pin input
Oscillation start signal
Oscillation start signal
"H"  "L"
within 500 ms
Crystal oscillation
circuit output
*1. 0 V means that there is no potential difference between the VDD pin and the VSS pin of the S-35740 Series.
Figure 29 When Power Supply Voltage is Raised at ENBL Pin = "H"
22