English
Language : 

S-8264AAA-I8T1U Datasheet, PDF (20/36 Pages) Seiko Instruments Inc – BATTERY PROTECTION IC FOR 2-SERIAL
BATTERY PROTECTION IC FOR 2-SERIAL TO 4-SERIAL-CELL PACK (SECONDARY PROTECTION)
S-8264A/B/C Series
Rev.4.2_02
 Battery Protection IC Connection Example
(1) 4-serial cell
SC PROTECTOR
BAT1
BAT2
BAT3
BAT4
RVDD
CVDD
R1
C1
R2
C2
R3
C3
R4
C4
External
input*1
RCTL
VDD
SENSE
VC1
S-8264A/B/C
Series
VC2
VC3
CO
VSS
CTL
EB+
FET
DP
EB−
Figure 13
*1. Refer to Table 13 for setting on external input.
Table 14 Constants for External Components
No.
Part
Min.
Typ.
Max.
Unit
1
R1 to R4
0.1
1
10
kΩ
2
C1 to C4, CVDD
0.01
0.1
1
μF
3
RVDD
50
100
500
Ω
4
RCTL
0
100
500
Ω
Caution 1. The above constants are subject to change without prior notice.
2. It has not been confirmed whether the operation is normal or not in circuits other than the above
example of connection. In addition, the example of connection shown above and the constant
will not guarantee successful operation. Perform thorough evaluation using the actual
application to set the constant.
3. Set the same constants to R1 to R4 and to C1 to C4 and CVDD.
4. Set RVDD, C1 to C4, and CVDD so that the condition (RVDD) × (C1 to C4, CVDD) ≥ 5 × 10−6 is satisfied.
5. Set R1 to R4, C1 to C4, and CVDD so that the condition (R1 to R4) × (C1 to C4, CVDD) ≥ 1 × 10−4 is
satisfied.
6. Since “H” may be output at CO transiently when the battery is being connected, connect the
positive terminal of BAT1 last in order to prevent the three terminal protection fuse from cutoff.
20