„ Timing Charts
1. Over charge detection
VCU
Battery
volta ge
VCD
VDU
VDD
VCC
DOP
terminal
VSS
V1 battery
V2 battery
V3 battery
COP
terminal
VMP
terminal
VSS
V CHA
VCC
V IOV1
VSS
C harg er
conne cted
Load
connected
Mode*1
Hi -z
Delay
c
d
Hi-z
Hi-z
Delay
c
d
De lay
c
Delay
c
*1. cNormal mode, dOver charge mode, eOver discharge mode, fOver current mode
Remark The charger is assumed to charge with a constant current. VCHA indicates the open voltage of the charger.