English
Language : 

S-8213AAB-I6T1U Datasheet, PDF (15/28 Pages) Seiko Instruments Inc – BATTERY PROTECTION IC FOR 2-SERIAL
Rev.1.3_03
BATTERY PROTECTION IC FOR 2-SERIAL / 3-SERIAL CELL PACK (SECONDARY PROTECTION)
S-8213 Series
 Battery Protection IC Connection Examples
1. 3-serial cell (CMOS output product)
SC PROTECTOR
BAT1
BAT2
BAT3
RVDD
CVDD
R1
C1
R2
C2
R3
C3
VDD
VC1
VC2
S-8213
Series
VC3
VSS
CO
EB+
FET
DP
EB−
Figure 14
Table 7 Constants for External Components
No.
Part
Min.
Typ.
Max.
Unit
1
R1 to R3
0.2
1
2
kΩ
2
C1 to C3, CVDD
0.01
0.1
1
μF
3
RVDD
50
100
500
Ω
Caution
1. The above constants are subject to change without prior notice.
2. It has not been confirmed whether the operation is normal or not in circuits other than the above
example of connection. In addition, the example of connection shown above and the constant
will not guarantee successful operation. Perform thorough evaluation using the actual
application to set the constant.
3. Set the same constants to R1 to R3 and to C1 to C3 and CVDD.
4. Set RVDD, C1 to C3, and CVDD so that the condition (RVDD) × (C1 to C3, CVDD) ≥ 5 × 10−6 is satisfied.
5. Set R1 to R3, C1 to C3, and CVDD so that the condition (R1 to R3) × (C1 to C3, CVDD) ≥ 1 × 10−4 is
satisfied.
6. Since CO pin may become detection status transiently when the battery is being connected,
connect the positive terminal of BAT1 last in order to prevent the three terminal protection fuse
from cutoff.
15