English
Language : 

C504 Datasheet, PDF (43/49 Pages) Siemens Semiconductor Group – 8-Bit CMOS Microcontroller
C504
AC Characteristics for C504-L40 / C504-2R40
VCC = 5 V + 10 %, – 15 %; VSS = 0 V
TA = 0 to 70 °C
for the SAB-C504
TA = – 40 to 85 °C
for the SAF-C504
(CL for port 0, ALE and PSEN outputs = 100 pF; CL for all other outputs = 80 pF)
Program Memory Characteristics
Parameter
ALE pulse width
Address setup to ALE
Address hold after ALE
ALE low to valid instr in
ALE to PSEN
PSEN pulse width
PSEN to valid instr in
Input instruction hold after PSEN
Input instruction float after PSEN
Address valid after PSEN
Address to valid instr in
Address float to PSEN
Symbol
Limit Values
40-MHz clock
Variable Clock
1/tCLCL = 3.5 MHz to
40 MHz
min. max. min.
max.
tLHLL
35
–
tAVLL
10
–
tLLAX
10
–
tLLIV
–
55
tLLPL
10
–
tPLPH
60
–
tPLIV
–
25
tPXIX
0
–
t *)
PXIZ
–
20
t *)
PXAV
20
–
tAVIV
–
65
tAZPL
–5 –
2tCLCL – 15
tCLCL – 15
tCLCL – 15
–
tCLCL – 15
3tCLCL – 15
–
0
–
tCLCL – 5
–
–5
–
–
–
4tCLCL – 45
–
–
3tCLCL – 50
–
tCLCL – 5
–
5tCLCL – 60
–
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
*) Interfacing the C504 to devices with float times up to 25 ns is permissible. This limited bus contention will not
cause any damage to port 0 drivers.
Semiconductor Group
43